Data Transmission - Roland XV-88 Manual Del Usuario

Ocultar thumbs Ver también para XV-88:
Tabla de contenido

Publicidad

MIDI Implementado
Data set 1DT1 (12H)
Status
Data byte
F0H
41H, dev, 00H, 10H, 12H, aaH, bbH,
ccH, ddH, eeH, ... ffH, sum
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
dev
Device ID (dev: 00H - 1FH, Initial value is 10H)
00H
Model ID #1 (XV-88)
10H
Model ID #2 (XV-88)
12H
Command ID (DT1)
aaH
Address MSB: upper byte of the starting address of the data to be sent
bbH
Address: upper middle byte of the starting address of the data to be
sent
ccH
Address: lower middle byte of the starting address of the data to be
sent
ddH
Address LSB: lower byte of the starting address of the data to be sent.
eeH
Data: the actual data to be sent. Multiple bytes of data are transmitted
in order starting from the address.
:
:
ffH
Data
sum
Checksum
F7H
EOX (End Of Exclusive)
* The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the address
and size given in "Parameter Address Map" (p. 279).
* Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.
* Regarding the checksum, please refer to (p. 294)
* Not received when the Rx Sys.Excl parameter (SYSTEM/MIDI/SYSTEM MIDI) is OFF.
Status
Data byte
F0H
41H, dev, 42H, 12H, aaH, bbH, ccH,
ddH, ... eeH, sum
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
dev
Device ID (dev: 10H)
42H
Model ID (GS)
12H
Command ID (DT1)
aaH
Address MSB:
bbH
Address:
ccH
Address LSB:
ddH
Data:
:
:
eeH
Data
sum
Checksum
F7H
EOX (End Of Exclusive)
* The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the address
and size given in "Parameter Address Map" (p. 279).
* Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.
* Regarding the checksum, please refer to (p. 294)
* Not received when the Rx Sys.Excl parameter (SYSTEM/MIDI/SYSTEM MIDI) is OFF.
276
Status
F7H
Status
F7H
upper byte of the starting address of the
transmitted data
middle byte of the starting address of the
transmitted data
lower byte of the starting address of the
transmitted data
the actual data to be transmitted. Multiple bytes
of data are transmitted starting from the address.

2. Data Transmission

Channel Voice Messages
Note off
Status
2nd byte
8nH
kkH
9nH
kkH
n = MIDI channel number:
0H - FH (ch.1 - 16)
kk = note number:
00H - 7FH (0 - 127)
vv = note off velocity:
00H - 7FH (0 - 127)
Note on
Status
2nd byte
9nH
kkH
n = MIDI channel number:
0H - FH (ch.1 - 16)
kk = note number:
00H - 7FH (0 - 127)
vv = note on velocity:
01H - 7FH (1 - 127)
Control Change
* By selecting a controller number that corresponds to the setting of parameters of
controllers (C1–C4 Assign, and so on), the XV-88 can transmit any control change
message.
Bank Select (Controller number 0, 32)
Status
2nd byte
BnH
00H
BnH
20H
n = MIDI channel number:
0H - FH (ch.1 - 16)
mm, ll = Bank number:
00 00H - 7F 7FH (bank.1 - bank.16384)
* These messages are transmitted when Performance, Patch or Rhythm set is selected. But
not transmitted when Program or Bank Sel parameter (SYSTEM/MIDI/TRANSMIT
MIDI) is OFF.
* In Performance (Zone) mode, these messages are not transmitted when Bank Select MSB
or P.C# parameter (ZONE/EXT CONTROL/EXT P.C) is NO-SEND.
* Although with the XV-88 you can select the Bank Select messages to be transmitted, be
sure to refer to the Program Change Map on (p. 270) for the Bank Select messages
transmitted when the XV-88 is select a Performance, Patch, or Rhythm Set.
* The Bank Select Numbers corresponding to SRX series should be referred to the SRX
series owner's manual.
Modulation (Controller number 1)
Status
2nd byte
BnH
01H
n = MIDI channel number:
0H - FH (ch.1 - 16)
vv = Modulation depth:
00H - 7FH (0 - 127)
Breath type (Controller number 2)
Status
2nd byte
BnH
02H
n = MIDI channel number:
0H - FH (ch.1 - 16)
vv = Control value:
00H - 7FH (0 - 127)
Portamento Time (Controller number 5)
Status
2nd byte
BnH
05H
n = MIDI channel number:
0H - FH (ch.1 - 16)
vv = Portamento Time:
00H - 7FH (0 - 127)
Data Entry (Controller number 6, 38)
Status
2nd byte
BnH
06H
BnH
26H
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = the value of the parameter specified by RPN/NRPN
mm = MSB, ll = LSB
* When execute the GM Data Transfer, Data Entry messages will transmit.
3rd byte
vvH
00H
3rd byte
vvH
3rd byte
mmH
llH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
mmH
llH

Publicidad

Tabla de contenido
loading