Greenlee GT-220 Manual De Instrucciones página 14

Verificadores eléctricos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Accuracy
Refer to "Specifications" for operating conditions and temperature
coefficient.
Accuracy is specified as follows: ± (a percentage of the reading + a fixed
amount) at 23 °C ± 5 °C (73 °F ± 9 °F), less than 75% relative humidity.
DCV (Auto V•Ω low impedance mode)
Range
6.000 V
60.00 V
600.0 V
1000 V
Input impedance: Initial 4.2 kΩ // 90 pF
Auto Check trigger lever: > +1.5 V typical; < –1.0 V typical
ACV (Auto V•Ω low impedance mode)
Range
6.000 V
60.00 V
600.0 V
1000 V
Input impedance: Initial 4.2 kΩ // 90 pF typical
Auto Check trigger lever: > 2.0 V (50/60 Hz) typical
Resistance (Auto V•Ω mode)
Range
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
* ± (0.9% + 0.024 kΩ) below 1.200 kΩ
Specification not guaranteed during first 2 minutes after measuring
voltages > 50 V.
Open circuit voltage: 0.4 Vdc typical
14
Accuracy GT-220
± (1.3% + 0.002 V)
± (1.3% + 0.01 V)
± (1.2% + 0.4 V)
± (1.5% + 8 V)
Accuracy GT-220
± (2.5% + 0.003 V)
± (2.5% + 0.03 V)
± (2.5% + 0.6 V)
± (2.8% + 8 V)
Accuracy GT-220
± (0.9% + 0.004 kΩ)*
± (0.9% + 0.04 kΩ)
± (0.9% + 0.1 kΩ)
± (1.2% + 0.004 MΩ)
Accuracy GT-540
± (0.8% + 0.002 V)
± (0.8% + 0.01 V)
± (1.2% + 0.4 V)
± (1.5% + 8 V)
Accuracy GT-540
± (1.5% + 0.003 V)
± (1.5% + 0.03 V)
± (2.0% + 0.6 V)
± (2.8% + 8 V)
Accuracy GT-540
± (0.9% + 0.004 kΩ)*
± (0.9% + 0.04 kΩ)
± (0.9% + 0.1 kΩ)
± (1.2% + 0.004 MΩ)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gt-540

Tabla de contenido