Troubleshooting - Dolmar RM-72.13 H Manual De Instrucciones

Ocultar thumbs Ver también para RM-72.13 H:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TROUBLESHOOTING

7.
TROUBLESHOOTING
PROBLEM
SITUATION
1. Pilot lamp off
Key is in «ON»
position,
engine
stopped
2. Starter motor
Key in
not working
«START» posi-
tion and pilot
lamp on
Key in
«START» posi-
tion and pilot
lamp flashing
3. Engine does
Key in
not start
«START» posi-
tion
LIKELY CAUSE
Electronic card in safety alert, due
to:
– badly connected battery
– completely flat battery or eroded
battery plates
– battery terminals crossed
– fuse blown
– badly earthed
– electronic card wet
– earthed micro-switches
– insufficiently charged battery
– battery charger fuse blown
– badly earthed
– you are not ready for starting
– no fuel supply
– faulty ignition
SOLUTIONS
Put the key in the «OFF» posi-
tion and look for the cause of
the problem:
– check connections
– recharge battery
– connect properly
– replace fuse (10 A)
– check connections
– dry by air
– check connections
– recharge battery (if the
problem continues, consult
a Licensed Service Centre)
– replace fuse (25 A)
– check connections
– Check that the conditions
allowing the start are met
(see page 26/a)
– check fuel level
– open fuel stop-cock (where
fitted)
– check the wiring of the fuel
open command (where fit-
ted)
– check fuel filter
– check that spark plugs
caps are firmly fitted
– check that the electrodes
are clean and have the cor-
rect gap
EN 39

Publicidad

Tabla de contenido
loading

Tabla de contenido