TABLE OF TECHNICAL FAULTS
PROBLEM
Radiator is not working
properly
The radiator does not
heat up
The radiator does not
ensure to reach the
desired temperature in
the room
Expansion noises in
switching on and/or off
phase
The radiator leaks oil
Window opening
detection does not
work properly
34
STATE OF THE
RADIATOR
"ALL" is displayed
The display does not
show any notice
Any
Properly working
Properly working
The symbol
is not
displayed and the
radiator is cold or
lukewarm.
The symbol
is
displayed
Any
Any
The symbol
is not
displayed
The symbol
is
displayed
PROBABLE CAUSE
The temperature
sensor is faulty
No power supply
Malfunction of resistor
or adjustment board
The radiator power is
insufficient to meet the
need of the room
The radiator position
affects excessively the
temperature detected
in the room
The temperature
set is lower than the
temperature of the
room.
"Child protection"
function is selected,
the radiator output is
lower than nominal
one.
Radiator supporting
brackets are not
centred and scrape on
the radiator.
Defect of the heating
body or lack of sealing
in connectors.
"Window opening"
function is not enabled.
Lowering of
temperature in
the rooms has not
exceeded 5°C in the
time provided or
the position of the
radiator does not allow
the probe to detect the
temperature correctly.
EN
SOLUTION
Contact a Service
Centre
Check the presence of
mains voltage
Contact a Service
Centre
Replace the radiator
with a more powerful
one or add another
radiator.
Relocate the radiator
Increase the
temperature set.
Deactivate "Child
protection" function
as shown in the proper
section of the manual.
Position brackets
properly.
Contact a Service
Centre.
Enable the function
as per the specific
paragraph of this
instruction manual
Relocate the radiator.