Adjusting The Direction Of The Exhaust; Clearing A Jam From The Tool - Campbell Hausfeld SB51400 Manual De Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Operating the Tool
(Continued)
3b. For
staples,
load a clip
of staples
with the
crowns straddling the magazine rail.
4. Push the
magazine
cover
forward
until latch
button pops up.
5. Always unload all fasteners before
removing tool from service.
Unloading is the reverse of loading,
except that you must disconnect
the air supply before unloading.
ADJUSTING THE FASTENER
PENETRATION
The tool is equipped with an adjustable
depth of drive feature. This allows the
user to determine how deep a fastener
will be driven into the work surface.
1. Adjust operating pressure so
fasteners are driven consistently. Do
not exceed 120 psi.
2. For shallow penetration, turn the
wheel (C) to right to the extent
desired.
(C)
3. For deeper penetration, turn the
wheel (C) to left to the extent
desired.
4. Make sure trigger and
work contact element
(WCE) move freely up
and down without
binding or sticking
after each adjustment.
www.chpower.com
ADJUSTING THE DIRECTION OF THE
EXHAUST
The tool is
equipped
with an
adjustable
Magazine rail
direction
exhaust deflector. This is intended to
allow the user to change the direction
of the exhaust. Simply twist the
deflector to any direction desired.

CLEARING A JAM FROM THE TOOL

1. Disconnect the air
supply from the tool.
2. Remove
all nails
from the
magazine
(See
Loading / Unloading The Nailer).
Failure to do so will cause the nails
to eject from the front of the nailer
when the nose assembly is removed.
the fasteners to eject from the front of
the tool.
3. Undo latch by pulling
out and down. The wire
latch will disengage
from the hooks on the
nose.
4. The door can now be
rotated, exposing the
jammed fastener.
5. Remove the jammed
fastener, using pliers
or a screwdriver if
required.
6. Rotate door back into
the closed position.
7. Extend the wire latch
and place over the
hooks on the nose.
Rotate
Failure to remove all
fasteners will cause
6
8. Close the latch by
pushing the latch up
and in until the latch
snaps into place.
9. Make sure the trigger
and work contact
element (WCE) move
freely up and down
without sticking or
binding.
Technical Support
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual.
Fastener and Replacement
Parts
Use only genuine
Campbell Hausfeld
16 gauge fasteners (or equivalent -
see Fastener Interchange
Information). Use only genuine
Campbell Hausfeld replacement
parts. Never substitute parts. Do
not use modifi ed parts or parts
which will not give equivalent
performance to the original
equipment. Tool performance,
safety and durability could
be reduced. When ordering
replacement parts or fasteners,
specify by part number.
Tool Repair
Only qualified personnel should repair
the tool, and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently.
Assembly Procedure for Seals
When repairing a tool, the internal
parts must be cleaned and lubricated.
Parker O-lube or equivalent must be
used on all o-rings. Each o-ring must be
coated with O-lube before assembling.
A small amount of oil must be used on
all moving surfaces and pivots.
After reassembling, a few drops of 30W
non-detergent oil or equivalent, must
be added through the air line before
testing.

Publicidad