Connecting The Battery - Husqvarna PP518 Manual De Instrucciones

Ocultar thumbs Ver también para PP518:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ASSEMBLING AND ADJUSTMENTS

Connecting the battery

The hydraulic unit is supplied with no battery cables
connected.
The original battery is maintenance free. Do not attempt to
open or remove caps or covers. It is usually not necessary to
check or adjust the level of electrolyte.
Replace only with a similar maintenance-free battery. See
information in the Technical data section.
WARNING! Lead-acid batteries produce
!
explosive gases. Avoid sparks, open flames
and smoking close to batteries.
Connecting or disconnecting the battery
may cause sparks and short circuits. Never
connect the battery terminal to keys, coins,
screws or other metal as this may short-
circuit the battery.
Batteries emit explosive gas. Sparks, flames
and cigarettes must absolutely not be
brought into the vicinity of the battery.
Unused batteries must be kept away from
metal objects such as nails, coins, jewellery.
Remove metal bracelets, watches, rings,
etc., before connecting the battery. Wear
gloves and protective goggles or a dust
mask when working with the battery.
Do as follows to connect the battery.
The battery is placed in the hydraulic unit's support foot.
1 Loosen the two knobs at the front of the support foot. Pull
out the battery using the two holes on the front edge. This
gives full access to the battery and cables.
2 Always connect the RED (+) cable to the positive (+)
battery terminal first. Attach the cable to the terminal using
the 5/16" screw and nut (13 mm or 1/2" wrench).
3 Connect the BLACK (-) grounding cable to the negative (-
) battery terminal. Attach the cable to the terminal using
the 5/16" screw and nut (13 mm or 1/2" wrench).
– 7
English

Publicidad

Tabla de contenido
loading

Tabla de contenido