A - CONTROL PANEL FEATURES
J4
J1
S3
TR2
J9
J5
J2
J8
J7
J6
J3
J10
2
J1
L-N
Main power supply 230Vac 50/60Hz upon request)
J2
COM
Common contact
LSC
Closing limit switch contact (NC)
LSO
Opening limit switch contact (NC)
LSSC
Closing slowing down limit switch contact (NO)
LSSO
Opening slowing down limit switch contact (NO)
TLC
Vehicle presence signal (NO) (only when switched to PARK mode)
PHOT. NC
Photocells contact (NC)
EDGE NC
Safety strip contact (NC)
COM
Common contact
D+ TEST
Safety strip self-test power supply +12Vdc 500mA max
D+
Accessories power supply +12Vdc 500mA max
D-
Accessories power supply -12Vdc 500mA max
J3
OPEN 2
Barrier opening button 2 contact (NO) (only when switched to PARK
mode)
SIGNAL
Barrier open signal 12Vdc
Buzzer - Acoustic signal connection (12Vdc max 200 mA)
AERIAL
Radio antenna
Blinker (max 40W)
J4
U - MOTOR
Motor common connection
V-W - MOTOR
Motor inverters and condenser connection
J5
OK CLOSE
Immediate closure command contact (only when switched to PARK
mode)
OPEN 1
Open1 button contact (NO)
CLOSE
Close button contact (NO)
STOP
Stop button contact (NC)
K BUTT.
Single pulse button (NO)
COM
Common contact (common line for all the commands and safety
inputs)
J6
PROBE
Heating probe connection terminal block (code ACG4666 optional)
J7
RADIO
Built in radio module
J8
AUX. ATT.
Card 1 relay connector (code ACQ9080) for management of courtesy
light or boom arm locking magnet
Card 3 relay connector (code ACQ9081) for management of courtesy
light or boom arm locking magnet and traffic lights.
J9
DO NOT TOUCH THE JUMPER!
IF REMOVED THE OPERATOR DOES NOT FUNCTION!
SW PARK
DO NOT TOUCH THE JUMPER!
J10
SW RADIO
IF REMOVED THE RADIO SYSTEM DOES NOT FUNCTION!
S3
PROG.
Programming button
TR2
TRIMMER LOW SPEED
Slow closure speed electronic regulator
22