CAUTION: Do not operate the product
between 1200 - 2600 rpm. The clutch
can disengage.
•
"GRIND": operate the product, 2600 - 3600 rpm.
Rpm for the grinding discs
The speed of the grinding discs is related to the speed
of the engine. The gauge (A) in the display shows how
much of the rpm for the engine that is used. When the
product is operated at engine speed 2600 rpm, the
speed of the grinding discs is 730 rpm. When the
product is operated at maximum engine speed, 3600
rpm, the speed of the grinding discs is 1010 rpm.
WARNING!
DO NOT OPERATE ENGINE BETWEEN 1200 - 2600 RPM
IDLE
To show and set the time in the display
The clock can show the current time, the total operating
time or the time until the servicing of the product.
•
To change the time:
a) Push and hold the menu button to go to selection
for clock.
b) Push the set button quickly to change the time.
•
To show the total operating time, push the menu
button quickly one time.
•
To show the time until next servicing, push the menu
button quickly 7 times until the letters SUC shows.
Carbon monoxide detector
After the engine starts, let the carbon monoxide detector
become warm and do a self-diagnostic routine for 5
minutes. During this time, the 2 LED indicators on the
carbon monoxide detector flashes. The top LED
indicator is green when the device operates correctly.
The top LED indicator flashes red if there is an error in
the device or the carbon monoxide sensor.
If the carbon monoxide values are more than 70 ppm,
the bottom LED indicator flashes red. Also the indicator
for check engine and carbon monoxide values on the
control panel comes on. The alarm stops automatically
when the carbon monoxide values are less then 50 ppm.
If the carbon monoxide values are more than 400 ppm,
the buzzer in the detector starts sound and the engine
stop. The alarm stops automatically and the engine can
be started when the carbon monoxide values are less
than 50 ppm.
6
rpm
A
DO NOT OPERATE
GRIND
1200
2600
RPM
Symbols on the product
WARNING: This product can be dangerous
and cause serious injury or death to the
operator or others. Be careful and use the
product correctly.
Read the manual carefully and make sure
that you understand the instructions before
you use the product.
Use hearing protection, eye protection and
respiratory protection. Refer to
protective equipment on page 8 .
WARNING! Dust can cause injuries if
inhaled. Use an approved breathing mask.
Avoid inhaling exhaust fumes. Always
provide for good ventilation.
Propane is very flammable and explosive.
Do not clean the carbon monoxide detector
with water or use water near the detector.
Always lift the product at the lifting eye.
Use the holes for tie-down straps to attach
the product to a transport vehicle.
The product is not domestic waste. Recycle
it at an approved disposal location for
electrical and electronic equipment.
Note: Other symbols/decals on the product refer to
special certification requirements for some markets.
Symbols on the control panel
Emergency stop.
Check engine or carbon monoxide values
are higher than permitted levels. If it is
necessary, speak to an approved service
agent.
Personal