Automatic mode (F2XX)
Opening: is started by operating the key device
(magnetic key, key switch, transmitter etc, in
accordance with the configuration F100, F101, F102).
• Collective opening (A901): during opening, the
control board does not obey key commands (the
gate cannot be stopped using key devices).
• Opening with alternative stop (A902): if a key
command is sent during opening, the gate comes to
a stop. A key command must be sent to close it.
• Opening with alternative stop and automatic
closing (A903): if a key command is sent during
opening, the gate stops and remains open for the
programmed time. If a key command is sent during
standby, standby time starts again.
4

OBSTACLE DETECTION FUNCTIONING

Detection by closing photocell S.CIE-FT1 (parameter C5) cable connectors P2 and P3
In swing gates, S.CIE (C5) refers to the exterior photocell (S.EXT).
During opening
If the closing photocell (S.CIE-FT1) is activated during
opening, the gate continues to open and the display
flashes OPC5.
Detection by opening photocell S.APE-FT2 (parameter C4) cable connectors P5 and P6
In swing gates, S.APE (C4) refers to the interior photocell.
During opening
If the opening photocell (S.APE-FT2) is activated during
opening, the gate stops and the display flashes OPC4; in
sliding (C302) and swing (C303) gates it also recedes
slightly; in dead-man mode, F103, the gate remains shut
down.
When the obstacle disappears, behaviour differs in
accordance with the type of door or gate selected:
• in swing gates (C301), the gate continues to open
• in sliding (C302) and swing (C303) gates, a closing
operation will be carried out when a key command
is received.
M239B
S t a n d b y : t h e g a t e r e m a i n s o p e n d u r i n g t h e
programmed time (except with the option A902, which
remains open until a key command is received). The
programmed time is indicated by the two final digits
(F201 indicates 01 second standby, F259 indicates 59
seconds, F24.0 indicates 4 minutes, which is the
maximum). The effect of activating the photocells or
key device during standby depends on the parameters
A8 and A7 respectively.
Closing: the closing operation starts once stand-by
time is finished.
If the key device is operated during closing, the gate
stops, reverses operation direction and then opens
completely.
During closing
If the closing photocell (S.CIE-FT1) is activated during
closing, the gate reverses direction and opens
completely (in dead-man mode F103, the gate remains
shut down). The display shows CLC5 and then flashes
OPC5, .
During closing
If the opening photocell (S.APE-FT2) is activated during
closing, the gate stops and the display flashesCLC4. The
gate opens when the obstacle disappears.
In dead-man mode, F103, the gate remains shut down,
and allows the closing operation to continue when the
obstacle disappears.