STARTING UP AND PROGRAMMING
Initial Conditions Programming (D1= "C")
D1 D2 Parameter
C
0
Number of operators
1
Operator 1 turning direction
(also changes operator 2)
2
Operator 2 turning direction
(also changes operator 1)
3
Type of gate
4
Safety device (photocell) in
opening (interior photocell
in swing gates, FT2)
5
Safety device (photocell) in
closing (exterior photocell in
swing gates, FT1)
C l o s i n g p h o t o ce l l w i t h
C520 or C521, also prevents
the start of gate opening
6
Electrolock / electromagnet
C630 and C640 are used to
manage an external relay at
24Vdc, connected to cable
connectors P11-P12. The
electromagnet must be
externally supplied (through
this relay) and sized in line
with the electromagnets
used.
7
Encoder / Limit switches
The connections depend on
t h e t y p e o f o p e r a t o r
selected (C301, C302 or
C 3 0 3 ) ;
c o r r e s p o n d i n g w i r i n g
diagram
8
Radio card
9
Safety strip
A
Slowdown
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
80
Installation Guide
D3
D4
0
1, 2
0
1, 2
0
1, 2
0
1...3
0,1
0,1
0...2
0,1
0...4 0...4
0
0...5
s e e
t h e
0
1, 2
0
1, 2
0
0...3
Default
Options
option
01
01: one operator, 02:two
available with C301)
01
01: direction A, 02: direction B
Check direction by pressing ST1 (open) and
ST2 (close)
01
01: direction A, 02: direction B
Check direction by pressing ST1 (open) and
ST2 (close)
01
01: swing,
02: sliding,
03: up-and-over
00
00: not installed,
10: no testing,
11: with testing
00
00: not installed,
10: no testing,
11: with testing,
20: no testing,
21: with testing
00
00: not installed
1X: electrolock
P r o g r a m m a b l e e l e c t r o l o c k t i m e : 3
seconds with X=0 (default), 3.5s with X=1,
4s with X=2, 4.5s with X=3, 5s with X=4.
2X: electrolock
Programmable time (electrolock/motor
reverse): 4.5/1.5 seconds with X=0 (by
default), 5/2s with X=1, 5.5/2.5s with
X=2, 6/3s with X=3, 6.5/5s with X=4.
30: electromagnet without impulse
40: drop electromagnet
00
00: not installed;
01: with single encoder
02: with limit switches;
03: with dual encoder;
04: with encoder and limit switches
(not available with C301 selected);
05: VULCAN VUS and ATLAS (ATS) G6xxl
(only available with C301 or C303
selected)
02
01: RSD card (non-decoding),
02: two channel decoder card
01
01: mechanical strip,
02: resistive strip 8k2
01
00: no slowdown,
01: slowdown in opening and closing;
02: slowdown in opening;
03: slowdown in closing
operators
(only
without
reverse
impulse.
with
reverse
impulse.

Hide quick links: