20. TABLE OF PARAMETERS (FOR SERIAL COMMUNICATION / HMI-SSW05-RS):
Parameter Function
Parameter
(Reading)
P000
Parameter Access
(2)
P002
Motor Current Indication (%)
P003
Motor Current Indication (A)
P023
Software Version
P030
R Phase Current
P031
S Phase Current
P032
T Phase Current
Status Indication of the
P050
motor overload protection
Parameter Function
Parameter
(Reading and Writing)
P101
Initial voltage
P102
Time of the Acceleration Ramp 1 to 20
P104
Time of the Deceleration Ramp 0 to 20
P105
Motor Current Setting
(1)
P106
Protection Configuration
(1)
P204
Load Factory Setting
(1)
P206
Auto-Reset Time
P215
Keypad Copy Function
(1)
HMI/(Trimpots and Dip Switch) 0 = Trimpots and Dip Switch
P220
(1)
Selection
Programmable Digital Input
P264
(1)
DI 1
Programmable relay output
P277
(1)
(14/23 - 24)
P295
Rated current of the Soft-Starter
(1) (2)
P308
Network Address
Action of the serial
P313
communication verification
Verification Time of the
P314
Serial Communication
P610
Immediate Undercurrent
P611
Immediate Undercurrent Time
(1)
These Parameters can be changed only with stopped motor.
These Parameters are not changed through the function "Loads Parameters with Factory Setting" (P204).
(2)
Installation and Operation Manual - SSW-05 Plus
Range of the
Internal Values
0 ... 4, 6... 9999 = Read
5 = Alteration
000,0 to 999,9
000,0 to 999,9
000,0 to 999,9
000,0 to 999,9
000,0 to 999,9
0 to 250
250 = error
Range of the
Internal Values
30 to 80
30 to 100
0 to 3F Hexadecimal
0 = No function
1 = No function
2 = No function
3 = No function
4 = No function
5 = Load factory default
1 to 1200
0 = Off
1 = Copy (SSW->keypad)
2 = Paste (keypad->SSW)
1 = HMI
0 = Not used
1 = Enable / Disable
2 = External Fault
1 = Full voltage
2 = Error
3 = Serial Com.
0 = 3 A
4 = 30 A
1 = 10 A
5 = 45 A
2 = 16 A
6 = 60 A
3 = 23 A
7 = 85 A
1 to 30
1 = only Error
2 = ramp disabling
3 = General disabling
4 = P2641
0 to 5
30 to 100
1 to 99
0 = Disabled
English-23
Factory
User
Unit
Setting
Setting
0
-
% In
A
-
A
A
A
-
Factory
User
Unit
Setting
Setting
30
% Un
10
s
0 = off
s
100
%
1F Hex.
-
0
-
900
s
0
-
0
-
1
-
1
-
According
to the
-
Type
1
-
-
1
0 = OFF
s
30
(%)
0
(s)
Page
24
24
24
24
24
24
24
24
Page
24
24
25
25
25
28
28
28
29
29
29
29
30
30
30
30
30