17.4

MWF pump

17.4.1

Operating instructions

The MWF pump has been designed to operate
in environments with atmospheres that are not
potentially explosive and it is ideal for pumping
aggressive, poorly lubricating or abrasive fluids.
Other liquids can be used only upon formal approval
by the Technical or Customer Service Departments.
17.4.2

Water temperature

The maximum permissible fluid temperature is 60°C.
For special cases it is best to contact our Technical or
Customer Service Departments.
17.4.3

Maximum pressure and flow rate

The rated specifications stated in our catalogue are the
maximum that can be obtained by the pump. Independently
of the power used, the maximum pressure and rpm indicated
in the specification label can never be exceeded unless upon
prior formal authorisation by our Technical or Customer
Service Departments.
17.4.4

Minimum rotating speed

Any rotating speed other than that indicated in the
performance table (see par. 17.4.5) must be expressly
formally authorised by our Technical or Customer Service
Departments.
17.4.5

Technical characteristics

For the technical characteristics of MW36-F and MW40-F
pumps, refer to table 5 for MW pumps.
17.4.6

Dimensions and weight

For the dimensions and weight of the MW36-F and MW40-F
pumps, refer to the diagram of the MW pump, Fig. 2.
17.4.7
Minimum rotating speed
For the exploded drawing and list of spare parts for the
MW36-F and MW40-F pumps, refer to the exploded view of
the MW H.P. pump on page 16.