17.5
MWM pump
17.5.1
Operating instructions
The MWM pump has been designed to operate
in environments with atmospheres that are not
potentially explosive and to operate with a high
percentage of dense fluids, whose recommended
maximum value of density is equal to ~ 1.05 kg/l.
17.5.2
Water temperature
The maximum permissible fluid temperature is 30°C.
However, the pump can be used with fluid up to
a temperature of 40°C, but only for short periods.
In this case, it is best to consult the Technical or
Customer Service Departments.
17.5.3
Maximum pressure and flow rate
The rated specifications stated in our catalogue are the
maximum that can be obtained by the pump. Independently
of the power used, the maximum pressure and rpm indicated
in the specification label can never be exceeded unless upon
prior formal authorisation by our Technical or Customer
Service Departments.
17.5.5
Technical characteristics
Model
MW55-M
17.5.6
Dimensions and weight
For MW55-M pump dimensions and weight, refer to Fig. 15.
Dry weight 270 kg.
Flow rate
Rpm
l/min
1300
238
80
17.5.4
Minimum rotating speed
Any rotating speed other than that indicated in the
performance table (see par. 17.5.5) must be expressly
formally authorised by our Technical or Customer Service
Departments.
Pressure
Gpm
bar
psi
62.9
100
1450
Power
kW
HP
44
60
Fig. 15