Mechanical safety strip connection (LB)
ENCODER1
ENCODER2
-FT
(Test)
P13 P14 P15 P16 P17 P18 P19 P20
P21 P22 P23
P1 P2 P3
P4 P5 P6
P7 P8
P9 P10
Resistive safety strip connection (LR)
ENCODER1
ENCODER2
-FT
(Test)
P13 P14 P15 P16 P17 P18 P19 P20
P21 P22 P23
P1 P2 P3
P4 P5 P6
P7 P8
P9 P10
P24 P25
MOTOR2
AUX
G4 G5
G6
24 Vdc
MOTOR1
P11 P12
G1 G2 G3
P144E
P24 P25
MOTOR2
AUX
G4 G5
G6
24 Vdc
MOTOR1
P11 P12
G1 G2 G3
LR
P144F
We recommend installing interior and exterior
strips. If only one is installed, install the exterior
one.
O
If neither a mechanical strip or a resistive strip is
installed, make an electrical bridge between cable
connectors P24 and P25 of the control board and
programme C901.
O
It is not possible to install mechanical and resistive
strips at the same time.
The mechanical strips are connected serially.
1 Connect the contacts of the strip in cable connectors
P24 and P25 of the control board.
2 Duly programme the control board:
Mechanical strip: C901
For further details on programming, see "Starting up
and programming" on page 59.
We recommend installing interior and exterior
strips. If only one is installed, install the
exterior one.
O
If neither a mechanical strip or a resistive strip is
installed, make an electrical bridge between cable
connectors P24 and P25 of the control board and
programme C901.
O
It is not possible to install mechanical and resistive
strips at the same time.
The resistive strips are connected in cascade.
1 Connect the end of the strip in cable connectors P24
and P25 of the control board.
2 Ensure the resistance (R) of 8.2kk is installed inside
the strip on the other end.
3 Check the installation: disconnect the control board
connector and connect an ohmmeter in the
connector: the value must be 8,200k ± 500k.
Operate the strip: the value must now be <1,000k.
4 Duly programme the control board:
Resistive strip: C902
For further details on programming, see "Starting
up and programming" on page 59.
INSTALLATION
57
VIVO-D201 Control board