EN
Blue keys coding:
- Adding new user keys: In normal mode pass through the front
reader the yellow key. A short sound will be heard. At this moment
pass the required number of blue keys to be linked. A sound will
be heard per each passed blue key. Finished this process pass
again the yellow key.
- Delete user keys: In normal mode, pass the red key. A short
sound will be heard. At this moment pass the required number of
blue keys to be unlinked. A sound will be heard per each passed
blue key. Finished this process pass again the red key.
5.4. Opening time configuration
The system allows selecting the opening tome of the electronic
lock when passing the user key. This time can be set to 1 second
or 5 seconds. For this adjustment it is required to use the second
jumper:
With the outdoor panel disconnected, set the jumper shorting the
fourth and fifth pins for 1 second or between the fifth and sixth pins
for 5 seconds.
6. OPERATING INSTRUCTIONS
- Call from outside. After pressing the call buton at the outdoor unit,
the indoor unit will sound and the visitor's image will be seen on the
display(s). Press the button
for 60 seconds time. Once finished the conversation press again
to hang up.
In case of expanded systems with one outdoor unit or two indoor
units:
- After pressing the call button at the outdoor unit with an al-
ready
the second outdoor unit will make a sound.
- Also in case that the call button of the outdoor unit is pressed, all
indoor units will sound and show the image of the visitor until one
indoor unit gets the call with
will enter into standby mode.
96
Opening time: 1 second
Opening time: 5 seconds
established
call
between
in order to establish communication
indoor
and
outdoor
. Once this happens all other units
Detail of the con-
figuration jumper
inside the outdoor
panel
unit,