CHANGE OF MEMBRANE
The membrane is a part subject to wear and tear. Its lifetime is dependent on various factors such as running
time, water hardness, water purity, etc. As soon as the fogging effect diminishes or stops, the fogging membrane
has to be replaced. These can be bought from your dealer. For assembly use the special key supplied.
Pull the mains receiver plug from the socket. Take the fogger out of the water and - if necessary - remove lime
deposits from around the fog membrane with vinegar water (the best way is to place the whole device in vinegar
water for about one hour). Prior to screwing open the thread ring the fogging device must be completely dry.
1 Thread ring
2 Membrane
(dark circle facing downwards)
3 Rubber sealing
Screw the thread ring (1) out anti-clockwise to the left with the aid of the special key. Carefully take out the
membrane (2) or the broken parts. If necessary, use a small screwdriver to do this. Take care that the rubber
sealing (3) is undamaged and properly fitted before putting the new membrane in.
Beware – the fogging membrane is fragile!
Fit the new membrane (2) properly (area with dark circle facing downwards). Screw the thread ring (1) back in
carefully in a clockwise direction. Your fogging device can now be used again.