EBARA Ego easy xx-100 Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
pressure begins to drop). At constant pressure, only the
pressure (Hset on the drawing) that the pump will
maintain constant can be set. The remaining parameters
can only be scrolled through.
Constant speed (Fig. 5.3c)
In this mode the pump maintains the
currently set speed constant (RPMset
on the drawing). It is therefore possible
to set only the speed that the pump
GB
will maintain constant; the remaining
parameters can only be scrolled through.
Night mode
The "night mode" is not an indipendent mode, it can
only be activated in combination with one of the above
mentioned modes.
When operating in night mode, the pump automatically
switches between the curve of the selected operating
mode to the night curve. Switching to the night mode
depends on the temperature of the fluid in the system:
when the pump senses that the temperature of the fluid has
dropped by 15-20C° (in 2 hours approx.), the icon starts to
flash and the pump switches to the night curve. When the
temperature of the fluid rises again, the icon stops flashing
and the pump switches over to the operating curve in the
selected operating mode.
In night mode the pump automatically set to lower head
and flow, thus assuring high saving energy during the night.
12. TWIN PUMPS
The main purpose of the twin pump is uninterrupted operation
if one of the pumps fails. During normal operation, only one
pump is active, while the other is in standby.
12.1 Twin Pumps with communcation module (Ego
TC easy)
Twin Pumps with communication module (Ego TC easy)
change duty once per day. Every pump operates according
to its own settings, so parameter changes should be made
on both pumps. If any pump detects an error or loss of
communication, the standby pump will start in less than
15 seconds. Common hydraulic housing is equipped with
a change-over flap, which opens regarding on the flow and
two pump heads, separately connected to the electrical grid.
This operation is only possible with the "Ego TC easy" models
and if both pumps are interconnected with a "crossover"
network cable. This is a factory set operation for all "Ego
TC easy" pumps. This operation is also possible on "Ego
easy" pumps with an additional communication module.
13. RESTORING THE FACTORY SETTING
To restore the factory settings of the pump, press and hold
all three keys for 5 seconds. The pump will be set to the
automatic mode of operation. The previously set values
of pressure and speed will be deleted.
14. MAINTENANCE AND REPAIR
Often control the plant trying to eliminate the disturbing causes
such as sand, lime, etc. Keep efficient the parts exposed
to damages (valves, filters, detectors and protections). For
interventions always call qualified technicians.
10
In case of long rests provide to often start the electropump.
Any replacement of the feeding cable as well as all other
maintenance operations must be performed only by the
assistance centre.
15. DEMOLITION
When demolishing the electropumps, follow strictly the
regulations in force in your country.
The user is responsible for disposing the equipment by
delivering it to a collecting point for recycling and disposal
of electrical equipment.
For further information about the collecting points of
equipment, contact your local authority for waste disposal,
or the shop where you purchased your product.
16. TECHNICAL DOCUMENTATION ATTACHED
Installation diagram.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ego easy xx-80Ego easy xx-60

Tabla de contenido