Mains supply to DATCOM components

General

Power is supplied to DATCOM components independently of the inverter. This ensures a
power supply when there is no power from the photovoltaic modules. Power is supplied to
DATCOM components via Fronius com cards or plug-in power packs. This is particularly
important when using a Fronius Sensor Card because this ensures that the datalogger will
be able to record all data even at night.
Power supply to
Fronius Com Cards are responsible for powering DATCOM components. The integrated
DATCOM compo-
power supply of a Fronius Com Card is implemented via special contacts in the slot, which
nents via Fronius
continue to supply power even when there is no power from the photovoltaic modules.
Com Card
Fronius Com Cards version 1.7 and higher are equipped with a switchedmode power sup-
ply and can be used with several supply voltages (208 V / 220 V / 230 V / 240 V / 277 V).
Up to version 1.4B:
Item number 4,070,769
(1)
10
WARNING! An electric shock can be fatal. Danger of an electrical shock due to
insufficient dimensioning for US-specific grid voltages. Fronius Com Cards up to
version 1.4B (item number 4,070,769) cannot be used with the Fronius IG Plus
USA.
AC fuse
(1)
Version 1.7 and higher:
Item number 4,070,913
(1)
Jumper
(1)