Manual de Usuario
________________________________________________________________________________________________________________________________
MODELO: 400/230V - PAG 2/2
XMART 33 (400V/230V) (Page 2/2)
OPERATING PARAMETERS / CONDICIONES OPERATIVAS
Efficiency (Line mode) / Eficiencia (Modo Línea)
Efficiency (Batt. mode) / Eficiencia (modo Batería)
Efficiency (ECO) / Eficiencia (ECO) (at 100% load)
Inverter Efficiency / Eficiencia del Inversor
Running Conditions / Condiciones de Operación
Noise / Ruido Acústico @ 1m
Altitude / Altura
Display / Display
Communication Ports / Puertos Com.
Communication Software / Software
Dimension UPS (D*W*H) cm
UPS (No batteries) - Net Weight / Peso Neto (kg)
UPS with Internal Batt. - Net Weight / Peso Neto (kg)
Battery Cab. XMART-33
Dimension "XMART33" EXT BATT (D*W*H) cm
Net Weight without Batteries / Peso Neto Vacio (Kg)
STD Runtime Config. / Configuración Estándar
Weight with STD batt. / Peso baterías estándar (Kg)
Battery Cab. ASB
Dimension ASB EXT BATT (D*W*H) cm
Net Weight without Batteries / Peso Neto Vacio (Kg)
STD Runtime Config. / Configuración Estándar
Weight with STD batt. / Peso baterías estándar (Kg)
SAFETY & STANDARDS / NORMATIVAS Y ESTANDARES
CE Directives
General Safety / Seguridad General
EMC
UPS Performance / Rendimiento UPS
Performance & Classification / Clasificación
Safety / Seguridad
ESD / RS / EFT / CS / Freq Mag. Field immunity
Surge protection / Protección contra Picos
Low Frequency Signals
Degree of protection / Grado de Protección
MTBF
Dielectric strength / Fortaleza Dieléctrica
Others
Transportation / Transporte
Technical specifications can be modified to comply with projects / Las especificaciones pueden modificarse para adaptarse a proyectos especiales
Technical specifications may change without further notice / Las especificaciones pueden cambiar sin previo aviso.
* Overload times in bypass mode are approximated. Time values depends of external parameters as room temperature, input frequency in Hz, etc
* Los tiempos de overload en modo bypass son aproximados. Pueden variar dependiendo de la temperatura de la sala, la frecuencia en Hz, etc
- XMART-33 UPS Series
20K
30K
95% / 94% / 91% / 90% (@ LOAD: 100% / 75% / 50% / 25%)
97% / 96% / 93% / 92% (@ LOAD: 100% / 75% / 50% / 25%)
(> 97 %)
(> 97 %)
( 0 - 40 º C ) - < 95%RH (non-condensing / no condensante)
Max Altitude: 4.500m. (over 1.000m output capacity is de-rated 1% every 100m) /
Altura máx 4.500msnm (sobre 1.000m la capaidad de salida disminuye 1% cada 100m)
70*45*110
118
190
(UPS only) (UPS only) (UPS only) (UPS only) (UPS only) (UPS only) (UPS only) (UPS only) (UPS only)
285
407
(62*9AH) (62*12AH) (62*18AH)
XBAT-20
XBAT-30
83*25*58 70*45*110 70*45*110 81*59*132 98*65*132
30
75
62*9AH
62*12AH
185
292
10020S
10020S
95*47*119 95*47*119 78*88*119 78*88*119 78*88*119 150*90*137 150*90*137 150*90*137 150*90*137
50
50
62*9AH
62*12AH
205
267
Inverter / Inversor: > 50.000 hours, PFC: > 250.000 hours
Designed for TUV and CE / Quality and Enviroment: ISO9001 & ISO14001
40K
60K
80K
(> 97 %)
(> 97 %)
(> 98 %)
96.5% (@ 100% load)
( < 52dB )
LCD+LED
Dry contact / Contactos Secos - RS232 / RS485 / SNMP
Windows family, Linux, Unix & Mac OS
81*59*132
192
202
222
527
x
x
XBAT-40
XBAT-60
XBAT-80
78
118
151
62*18AH
62*26AH
62*40AH
413
614
926
10032D
10032D
10032D
91
91
91
62*18AH
62*26AH
62*40AH
426
587
866
73 / 23 & 93 / 68 (LV Safety) and 89 / 336 ( EMC )
IEC 62040 - 1 - 1
EMC Radiation: IEC 62040 - 2 ( Class C3 compliant )
IEC 62040 - 3
VFI - SS - 111 according to EN - 62040 - 3
IEC / EN60950 - 1
EN 61000 - 4 - 2 / 3 / 4 / 5 / 6 / 8 (level 3)
IEC / EN 61000 - 4 - 5 Level 3
IEC / EN 61000 - 2 - 2
IP20
IEC / EN 62040 - 1
ETS 300019 - 2 - 2 class 2.3
ESPAÑOL
100K
120K
160KVA 200KVA
(> 97 %)
(> 97 %)
(> 97 %)
85*90*190
255
259
550
x
x
x
(Ext. Batt Only)
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
10064D
10064D
10064D
175
175
175
62*65AH
62*100AH
62*100AH
1,365
2,035
2,035
171129 - XMART33 (ESP)
(> 97 %)
560
x
x
x
x
x
x
10064D
175
62*100AH
2,035
- 82