Polar CK640 Manual De Instrucciones página 12

Ocultar thumbs Ver también para CK640:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 74
UK
To start the cycle:
During chilling:
If the temperature
measured by
the pin probe
reaches the
chilling endpoint
temperature prior
to expiry of the
maximum chilling
time duration:
If the temperature
measured by the
pin probe does
not reach the
chilling endpoint
temperature prior
to expiry of the
maximum chilling
time duration:
If the temperature
measured by
the pin probe
reaches the
chilling endpoint
temperature:
12
CK640_ML_A5_v4_20200728.indb 12
CK640_ML_A5_v4_20200728.indb 12
ensure the device is in "stand-by" mode and no procedures are running
press
to select "nEg" and ensure the LED
press
or
within 15 seconds: the display will show the blast
chilling end-point temperature
press
or
within 15 seconds to change the value (the setting
remains active until another cycle is selected, when the value assigned by
parameter r4 is restored)
press
: after 2 minutes, the appliance will run set-temperature negative
chilling and storage cycle
the display shows the temperature measured by the pin probe
the LED
is on
the parameter r4 sets the chilling endpoint temperature
the parameter r6 sets the maximum chilling time duration
the parameter r8 sets the operational set point
press
several times to:
- display the maximum residual chilling time remaining
- display the message "nEg"
- display the flashing cabinet temperature
- exit the procedure, or leave for 15 seconds
the device will switch to storage mode
the display will show the message "End"
the buzzer will sound for the period of time set by parameter AA
press any key to mute the buzzer; press once more to cancel the message
"End"
chilling will continue
the LED
will flash and the LED
the buzzer will sound
press
several times to:
- mute the buzzer
- display the time elapsed since the maximum chilling time expired
- display the cabinet temperature
- display the message "nEg"
- exit the procedure, or leave for 15 seconds
the device switches to storage mode
the LED
will continue to flash and the LED
the display will show the message "End"
the buzzer will sound for the period of time set by parameter AA
press any key to mute the buzzer; press once more to cancel the message
"End"
is flashing
will be on
will continue to stay on
2020/7/28 17:38
2020/7/28 17:38

Publicidad

Tabla de contenido
loading

Tabla de contenido