Troubleshooting
No display/partial
display/unit
will not turn on
Unit operates but Telemetric
HR not displayed
No speed/RPM reading
Electrical (wall) outlet
Connection at front of unit
Main console cable integrity
Main console cable connections/
orientation
Console display for cracks or other
damage
Console Display
Chest Strap
Interference
Chest Strap
Main console cable integrity
Main console cable connections/
position
Magnet position (requires shroud
removal)
RPM Sensor (requires shroud
removal)
If outlet does not function, use a properly
functioning
outlet.
Connection should be secure and undamaged.
Replace adapter or connection
at unit if damage
appears.
Replace cable if wires appear crimped or cut.
Confirm cable is connected securely atthe back
of the console and atthe base of the console
mast.
Replace console if damaged.
Replace computer
if console only has partial
display.
Make sure strap is directly against skin and
contact area is moist. Strap should be Polar ®
compatible.
Try moving unit away from sources of interference
(TV, Microwave, etc).
Connect strap to a functioning Polar® compatible
device to see if it works. If it does not function,
replace strap. If strap works with other devices
but not with the Schwinn ® 460, replace HR
receiver.
All wires in cable should be intact. Replace cable
if wires appear crimped or cut.
Confirm cable is securely connected and
properly positioned. Small latch on connector
should line up and snap into place.
Replace flywheel or entire main assembly if you
do not see a magnet.
RPM sensor should be aligned with magnet
and connected to data cable. Re-align sensor
if necessary. Replace if there is any damage to
sensor or connecting wire.