ABORTED CHARGE
If charging cannot be completed normally, charging will abort. When charging
aborts, the charger's output is shut off, and the BAD BATTERY
Do not continue attempting to charge the battery. Have the battery checked and
replace, if necessary.

10. MAINTENANCE AND CARE

10.1 After use and before performing maintenance, unplug and disconnect the battery charger.
10.2 Use a dry cloth to wipe all battery corrosion and other dirt or oil from the connector,
cords and the charger case.
10.3 Store inside, in a cool, dry place.

11. TROUBLESHOOTING

PROBLEM
CHARGING/CHARGED
LED is flashing.
BAD BATTERY
is lit.
The charger will not
turn on when properly
connected.
I cannot select a 6V or
12V setting.
POSSIBLE CAUSE
The battery's charge is
80% or higher.
LED
Charger is in abort mode.
AC outlet is dead.
Poor electrical connection.
Battery is defective.
The charger is equipped
with Auto Voltage Detection,
which automatically detects
the voltage and charges the
battery.
No problem; this is normal.
Do not continue trying to
charge the battery. Have the
battery checked or replaced.
Check for open fuse or
circuit breaker supplying the
AC outlet.
Check power cord and
extension cord for a loose
fitting plug.
Have the battery checked.
No problem; this is normal.
• 9 •
LED will light.