Leuchtkraft ODC-100/CTW Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
3.2 Barn doors
To reduce the light beam angle, optional barn
doors are available: PARC-100B . Fasten the barn
doors to the front of the spotlight .
3.3 Power supply
When the spotlight has been connected to the
mains, it is switched on . The display will show
the menu item most recently selected and go out
after 30 seconds . As soon as a button (MENU,
ENTER, UP or DOWN) is pressed, the display will
light up again for 30 seconds .
WARNING To prevent damage to your eyes,
never look directly into the light
source for any length of time .
Please note that fast changes in
lighting may trigger epileptic sei-
zures with photosensitive persons
or persons with epilepsy!
3.3.1 ODC-100 / CTW
Connect the plug (A) of the cable POWER IN to
the inline jack (B) of the mains cable provided .
Then fasten the nut to secure this connection .
POWER IN
A
Fig. 4 Mains connection ODC-100 / CTW
CAUTION! The cable POWER OUT carries mains
voltage . If no further unit is connected to the ca-
bles POWER OUT and DMX OUT, always screw the
protective covers supplied onto the inline jacks .
Connect the mains plug to a socket (230 V/ 50 Hz) .
Power supply
of multiple ODC-100 / CTW spotlights
If multiple ODC-100 / CTW spotlights are used, the
units can be interconnected for power supply . For
the time being, do not yet connect the first unit
to a mains socket .
1) Use the inline jack of the cable POWER OUT
to connect the first unit to the plug (A) of the
cable POWER IN of the second unit . Proceed
in the same way to connect the second unit
to the third one etc . until all units have been
connected in a chain .
If the mains connection cables between the
spotlights are too short, use suitable extension
cables, e . g .
ODP-34AC
length: 2 m or
ODP-34AC / 10 length: 10 m
B
230 V/50 Hz
CAUTION! To reduce the risk of cable fire
caused by overload, the total current in the
connection cables must not exceed 10 A .
Therefore, do not interconnect more than 19
ODC-100 / CTW spotlights .
2) On the last spotlight, screw the protective
cover supplied onto the inline jack of the cable
POWER OUT . The cable carries mains voltage!
3) Connect the mains plug of the first spotlight
to a mains socket (230 V/ 50 Hz) .
3.3.2 PARC-100 / CTW
For power supply, the unit is equipped with
Powercon connections .
CAUTION! Never connect or disconnect a Power-
con plug while voltage is applied . Always make
the Powercon connection before making the
mains connection . When disconnecting, always
disconnect the mains connection before discon-
necting the Powercon connection .
Connect the mains jack POWER IN to a mains
socket (230 V/ 50 Hz) via the mains cable provided .
Connect the blue Powercon plug of the cable to
the mains jack, and then turn the plug clockwise
until it locks . To remove the plug, pull back the
safety latch of the plug and turn the plug coun-
ter-clockwise .
Power supply
of multiple PARC-100 / CTW spotlights
If multiple PARC-100 / CTW spotlights are used,
the jack POWER OUT of the first spotlight can
be connected to the mains jack POWER IN of
the second spotlight . For this, a mains cable with
Powercon plugs (NAC-3FCB and NAC-3FCA) is
required . Proceed in the same way to connect the
second spotlight to the third spotlight etc . until
all spotlights have been connected in a chain .
Thus, up to 19 spotlights can be interconnected .
The jack POWER OUT can also be used for power
supply of other (light effect) units .
CAUTION! To reduce the risk of fire caused by
overload, the current load of the cables and the
mains plug must not exceed 10 A .
9

Publicidad

Tabla de contenido
loading

Productos relacionados para Leuchtkraft ODC-100/CTW

Este manual también es adecuado para:

Parc-100/ctw38.708038.7110

Tabla de contenido