GB
GB
3
Transportation and storage
3.1
Transportation
The pellet stove has to be only transported in the vertical position, in the original package and with properly fixation against movement and
falling. Transportation has to be performed in close space in order to avoid damage from atmospheric conditions. During handling it is necessary
to follow the vertical position; the stove mustn't be declined in any way to avoid its damaging. The stove has to be griped and convey by the
bottom metal parts.
After taking-over the product, please properly check integrity and completeness of the package, including its content.
3.2
Storage
The pellet stove has to be stored in a dry and tempered environment. It is necessary to store and handl it in the vertical position. Please be extra
careful during handling.
4
Placement and installation
4.1
Regulations and directives
EN 14 785:2007
ČSN 73 4230
EN 1443
ČSN 73 4201
EN 13501-1+A1
ČSN 06 1008
4.2
General instructions for placement and installation
Each pellet stove has to be implicitly placed and installed so that there were observed the conditions specified by local regulations or national
and European norms as amended, including their additions, as well as in accordance with instructions specified in this instruction manual.
The pellet stoves are determined for installation in dry premises that are characterized by a valid norm as unaggressive environment without any
explosive are combustible gases.
Before installation of pellet stoves it is necessary to carry out revision of the breast, into which the stove has to be connected, including design
and assessment of the flue channel, which has to provide safety exhaust of flue gases from the connected stove. Only one consumer can be
connected to the flue channel.
At installation it is necessary to provide sufficient access for cleaning of the consumer, the flue gas ducting and the chimney.
In interior where a pellet stove is placed, it is not recommended to place equipment for air exhausting (for example, a fume hood), which could
invoke backward draught and leakage of flue gases into a room. If anyhow this equipment is placed in the interior, it is necessary to provide
regulation of its draught and suction of combustion air from an extern room (a cellar, a technical room, etc.). Only overpressure air conditioning
can be used.
Fig. №. 3
Dismantling the fireplace from the pallet
1.
Unscrew the rear casing of the fireplace.
2.
Using the wrench no. 17, unscrew 2 nuts M10 connecting the fireplace and the pallet.
3.
Mount the rear casing back.
4.
Place the fireplace to the desired location. When placing, rules see chap. 3.4 must be adhered to.
Pellet stoves.
Hearths with open and closed fire grates.
Chimneys – General requirements.
Hearths and smoke-flues – Design, implementation and connection of fuel consumers.
Fire protection classification of building products and building structures.
Fire safety of heating equipment.
82
1.
Rear casing
2.
Nut M10