GB
GB
6.5
Room thermostat value adjustment mode
Set the required temperature in the room according to MENU 2.2 and 2.2.1. This temperature is scanned from the room thermostat, which is a
part of your pellet stove. It is a black cable with the length of approximately 80 cm, on the end of which there is an oval-shaped sensor. Place
this sensor, for example, on the floor near the stove, or behind the pellet stove. You may adjust whenever during operation or in the shutdown
state.
6.6
Pellet supply and exhaust fan rpm adjustment mode
Each pellet stove is placed in different environment and in different geographic conditions, and that is both atmospheric and pressure ones.
Somewhere the stove seems is combusting too "quickly", and, on the contrary, somewhere too "slow", although the system is automatically
controlled. That's why you as a user may set the pellet supply speed of the feeding auger, and that is in MENU 2.1 and 2.1.2 in the given limits,
as well as the exhaust fan speed, and that is in MENU 2.1 and 2.1.3 also in the given limits. If it is necessary, adjust new values, but
recommend settings of the producer.
6.7
Alarms on the display and their removal
Mistake description
Too high voltage on the input to the stove (signalized even in the
shutdown state)
The furnace door is opened
Extinguishing process was untimely terminated by a user
Exceeded temperature in the pellet reservoir
A failure of the exhaust fan sensor – no signal
A failure of the exhaust fan sensor – fan regulation doesn't work
Date and time is set incorrectly
A mistake during ignition
Low power supply voltage
Insufficient pellet quantity
A failure of the pellet auger sensor – no signal
A failure of the pellet auger sensor – auger regulation doesn't
work
UNBLOCKING procedure: press the button ON/OFF for at least 3 sec, the system will be reset and start into the normal state.
The status
on the
Code
Method of removal
display
• Switch-off the equipment and perform check
of electric voltage, wait up and switch-on the
Er01
Block
equipment again.
• Call service
• Close the door, unblock
Block
Er02
• Unblock and wait up to the extinguishing
Block
Er05
process is terminated.
• Check up the receiving hopper, if needed,
Er06
Block
extinguish, unblock
• Call service
Block
Er07
• Call service
Block
Er08
• Set according to MENU 3.1.1
Er11
Block
• The flue gases temperature sensor is
withdrawn during the extinguishing process.
Block
Er12
Insert the sensor back.
• Call service
• Switch-off the equipment and perform check
of electric voltage, wait up and switch-on the
Block
Er15
equipment again.
• Call service
• Refill pellets to the reservoir
Block
Er18
• Call service
Block
Er47
• Call service
Block
Er48
92