FX2N Series Programmable Controllers
Table 1.6:
ENG
Special function blocks FRE - Modules spéciaux
-
ITL
- Moduli speciali
MODEL
FX-2DA
Digital to analog converter
FX-4DA
Digital to analog converter
FX-4AD
Analog to digital converter
FX-2AD-PT
PT100 probe interface
FX-4AD-TC
Thermo-couple interface
FX-1HC
High speed counter
FX-1PG-E
Pulse output, Position control
FX-16NP/NT
Net-mini interface
FX-16NP/NT-S3 Net-mini-S3 interface
FX-1GM
Position Control (1 axis)
FX-10GM
Position Control (1 axis)
FX-20GM
Position Control (2 axis)
FX Special functions blocks must be connected at the right end of the system using the FX
ENG
CNV-IF convertion interface.
Des blocs de fonctions spéciales FX doivent être connectés à l'extrémité droite du système en
FRE
utilisant l'interface de conversion FX
Die FX-Sondermodule müssen an der rechten Seite der Systemkonfiguration über die
GER
Schnittstelle FX
I blocchi delle funzioni speciali FX devono essere collegati con l'estremità destra del sistema
ITL
usando l'interfaccia di conversione FX
El bloque funcional especial FX debe ser conectado al extremo derecho del sistema a través
ESP
de la interfase de conversión FX
NUMBER
DESCRIPTION
8
-CNV-IF angeschlossen werden.
2N
2N
ESP - Módulos especiales blocks
POWER SUPPLY
OF I/O
Internal
External
I
O
5V DC
24V DC
-
8
-
30mA
130mA
-
8
-
30mA
200mA
-
8
-
30mA
50mA
-
8
-
30mA
50mA
-
8
-
40mA
60mA
-
8
-
70mA
-
8
-
60mA
40mA
16
8
80mA
120mA
8
8
80mA
100mA
-
8
-
AC supply
-
8
-
-
210mA
-
8
-
AC supply
-CNV-IF.
2N
-CNV-IF.
2N
-CNV-IF.
*
GER - Sondermodule
DIMENSIONS
mm
(inches)
73 (2.9)
140
(5.5)
-
45 (1.8)
73 (2.9)
160
(6.3)
140
50 (1.9)
(5.5)
110
(4.3)
Introduction 1
MASS
(WEIGHT)
kg
(lbs)
0.5 (1.1)
0.3 (0.66)
0.5 (1.1)
95
(3.7)
0.3 (0.66)
0.4 (0.88)
1.5 (3.3)
95
(3.7)
0.4 (0.88)
-
2N