Descargar Imprimir esta página

Binks AA4400M Manual De Servicio página 10

Ocultar thumbs Ver también para AA4400M:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
EN
REASON TO INSTALL TIP GUARD:
To replace broken tip guard.
!
For pressures over 69 bar [1000 psi] the tip guard must be in place for
added protection against skin injection.
!
Always ensure that all fluid and air pressure to the gun has been dis-
charged before proceeding with any repairs.
INSTRUCTIONS ARE VALID FOR BOTH FLAT TIP GUARD
AND TWIST TIP GUARD:
1. Disconnect all fluid and air hoses from the gun.
2. Insert the gun into a clamping vise with fluid nozzle facing
directly upwards. (See fig 37) Gun should be securely clamped
at the upper portion of the gun handle.
3. Assemble air cap and air cap ring together – less spray tip and
plastic tip guard. (See fig 38)
4. Install the air cap and air cap ring assembly onto the gun until it
is fully hand tightened. (See fig 39)
5. Slip on the plastic tip guard onto the air cap in proper
orientation. (See fig 40)
6. Place round bar screwdriver between open sections of the
plastic guard and push down with even pressure on both sides
of the plastic guard. (See fig 41)
7. The guard should snap into air cap groove securely. (See fig 42)
8. The aircap can now be removed to install the appropriate tip
for use.
TIP GUARD INSTALLATION
WARNING
CAUTION
Fig. 37
Fig. 39
Fig. 41
10 / 13
Fig. 38
Fig. 40
Fig. 42
77-2922-R10.1 (2/2016)