Fig. 9.3
IMPORTANT:
The gasket "B" (fig. 9.2a - 9.2b) is the
element that guarantees the seal in the
gas connection. It is recommended that
it be replaced whenever it shows even
the slightest deformation or imperfection.
To replace the conical connector "C" or
the hose connector "D" it is necessary to
operate with 2 spanners (fig. 9.3).
After connecting to the mains, check
that the couplings are correctly
sealed, using soapy solution, but
never a naked flame.
158
Gas maintenance
REPLACEMENT OF BURNER
INJECTORS
Select the injectors to be replaced
according to the "Table for the choice of
the injectors".
To replace the injectors proceed as fol-
lows:
- Remove pan supports and burners
from the cooktop.
- Using a wrench, substitute the nozzle
injectors "J" (fig. 9.4a, 9.4b) with those
most suitable for the kind of gas for
which it is to be used.
J
Fig. 9.4a
J
Fig. 9.4b