Technical Data; Before Use; Tool Inspection - Hilti DX 462 Manual De Instrucciones

Ocultar thumbs Ver también para DX 462:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

X-EKB
X-ECH
X-ET
X-(E)M/W/6/8 ... P8,
X-M/W10 ... P10
X-DNH / DKH,
X-M6/8H
Please contact your local Hilti Center or Hilti representative for details of other fasteners and accessories.
Cartridges
Ordering designation
6.8/11 M green
6.8/11 M yellow
6.8/11 M red
6.8/11 M black
Cleaning set
Hilti spray, flat brush, large round brush, small round brush, scraper, cleaning cloth.

5. Technical data

DX 462 tool
Weight
Tool length
Nail length
Recommended maximum fastening rate
Cartridges
Power regulation

6. Before use

aa
6.1

Tool inspection

● Ensure that there is no cartridge strip in the tool. If
there is a cartridge strip in the tool, remove it by hand
from the tool.
● Check all external parts of the tool for damage at reg-
ular intervals and check that all controls operate prop-
erly. Do not operate the tool when parts are damaged or
when the controls do not operate properly. If necessary,
have the tool repaired at a Hilti service centre.
● Check the buffer and piston for wear (see "8. Care
and maintenance").
6.2 Choosing the right fastener guide / piston / fas-
tener combination
Use of the wrong combination may present a risk of
injury. Damage to the tool may also result or fastening
quality may be negatively affected.
Printed: 08.07.2013 | Doc-Nr: PUB / 5069845 / 000 / 02
Cable clasp for fastening electric cables flat on ceilings and walls
Bunched cable holder for fastening cables on ceilings and walls
Fastener for plastic (PVC) electric cable trunking
Studs for bolted fastenings on concrete and steel
Approved fastening system for use on concrete, predrilling required
Colour code
Green
Yellow
Red
Black/purple
Power level
Low
Medium
Heavy
Extra heavy
3.1 kg
405 mm
Max. 47 mm
700 per hour
6.8/11 M (27 cal. short) green, yellow, red, black
4 cartridge power levels, regulation wheel with locking
function
aa
6.3
Changing the fastener guide
1. Ensure that no cartridge strip or fastener is loaded in
the tool. Remove the cartridge strip by pulling it
upwards out of the tool and remove the fastener from
the fastener guide.
2. Press the release button on the side of the fastener
guide.
3. Unscrew the fastener guide.
4. Check the buffer and piston for wear (see "Care and
maintenance").
5. Push the piston into the tool as far as it will go.
6. Press the buffer onto the fastener guide until it snaps
into place.
7. Push the fastener guide firmly onto the piston return
unit.
8. Screw the fastener guide onto the tool until it engages.
en
21

Publicidad

Tabla de contenido
loading

Tabla de contenido