Description of connections

Figures 1-2-3-4 show connection diagrams.
5.1

Typical installation

1
8
9
5
1
Power supply
2
Connection Motor1 to control panel
3
Connection Motor2 to control panel
Encoder connection
Photocell - Receiver
4
Photocell - Transmitter
5
Key selector R85/60
6
Keypad H85/TTD - H85/TDS (connecting to control panel to decoder
board H85/DEC - H85/DEC2)
Flashing light R92/LED230 - FIFTHY/230
Power supply 230Vac - LED
7
Antenna
8
Gate open indicator
9
Courtesy light
SUGGESTIONS: with existing installations, we recommend checking the cross section of the cables and that the
cables themselves are in good condition.
50
7
6
4
2
4
Recommended cable
H07RN-F 3x1,5 mm2 double insulated cable
2
Cable 4x1,5 mm
2
Cable 4x1,5 mm
2
Cable 3x0,5 mm
(max 30 m)
2
Cable 4x0,5 mm
(max 20 m)
2
Cable 2x0,5 mm
(max 20 m)
2
Cable 3x0,5 mm
(max 20 m)
2
Cable 3x0,5 mm
(max 20 m)
Cable 2x1 mm
2
(max 10 m)
Cable tipo RG58 (max 10 m)
Cable 2x0,5 mm
2
(max 20 m)
Cable 2x1 mm
2
(max 20 m)
5
3

Publicidad

loading