7. Starting, operation
Specifications
Model HP-2
Materials
Wetted parts
Case
Power supply U
U
in VDC
B
B
Signal output and
R
in Ohm
A
maximum ohmic load R
A
Adjustability zero
%
Response time (10 ... 90 %)
ms
Insulation voltage
VDC
Accuracy
% of span
% of span
*
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
)
error of measurement per IEC 61298-2).
1-year stability
% of span
Permissible temperature of
Medium **
)
Ambience **
)
Storage **
)
**
)
Also complies with EN 50178, Tab. 7, Operation (C) 4K4H, Storage (D) 1K4,
Transport (E) 2K3
Rated temperature range
Temperature error within
%
rated temperature range
RoHS- conformitiy
12 WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio HP-1/HP-2
1.4534
Stainless steel
10 ... 30 (14 ... 30 with signal output 0 ... 10 V)
≤ (U
4 ... 20 mA, 2-wire
R
– 10 V) / 0.02 A
A
B
0 ... 5 V, 3-wire
RA > 5,000
0 ... 10 V, 3-wire
RA > 10,000
Other signal output on request
±
5 using potentiometers inside the instrument
≤ 1
500
±
0.5 *
)
±
0.25 *
on request
)
≤ 0.1
(at reference conditions)
-0 ... +80 °C
32 ... +176 °F
-20 ... +80 °C
-4 ... +176 °F
-40 ... +85 °C
-40 ... +185 °F
0 ... +80 °C
32 ... +176 °F
≤ 1.0 typ.
≤ 2.5 max.
on request
GB
7. Starting, operation
Specifications
CE- conformitiy
Pressure equipment directive
EMC directive
Shock resistance
Vibration resistance
Wiring protection
Short-circuit proofness
Reverse polarity protection
Weight
When designing your plant, take into account that the stated values (e.g.burst pres-
sure, over pressure safety) apply depending on the material and thread used.
The respective values for your mounting torque and maximum pressure please
find in the documentation of your high-pressure equipment supplier.

Functional test

The output signal must be proportional to the pressure. If not, this might point to a
damage of the diaphragm. In that case refer to chapter 10 „Troubleshooting".
Open pressure connections only after the system is without pressure!
Observe the ambient and working conditions outlined in section 7 „Technical
data".
Warning
Please make sure that the pressure transmitter is only used within the over-
load threshold limit at all times!
When touching the pressure transmitter, keep in mind that the surfaces of
the instrument components might get hot during operation.
Caution
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio HP-1/HP-2
Model HP-2
97/23/EC
2004/108/EC, EN 61 326 Emission (Group 1, Class B) and Immunity
(industrial locations)
g
100 (2.4 ms)
according to IEC 60068-2-27
mm
0.35 (10 ... 55 Hz)
according to IEC 60068-2-6
Sig+ towards UB-
UB+ towards UB-
kg
Approx. 0.3