Trouble Shooting - Ingersoll Rand SSR UP5-4 Manual De Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLe SHOOTInG

TROUBLe SHOOTInG
PROBLeM
Compressor fails to
start
Machine shuts down
periodically
High current draw
Low current draw
High discharge
pressure
Low system air
pressure
High dewpoint
Ice formation in dryer Low evaporator pressure.

CAUSe
Mains power or Control voltage not
available.
Defective Star / Delta timer.
High airend temperature.
Motor overload.
Line voltage variation.
Compressor operating above rated
pressure.
Separator cartridge contaminated.
Low voltage.
Unbalanced voltage.
Damaged airend.
Air filter contaminated.
Compressor operating unloaded.
High voltage.
Defective inlet valve.
Defective or incorrect pressure switch
setting.
Blowdown valve defective.
Inlet valve malfunction.
Separator cartridge contaminated.
Incorrect pressure transducer setting
Minimum pressure valve malfunction.
Blowdown valve defective.
Drive belt slipping.
Air system leaks.
Inlet valve malfunction.
System demand exceeds compressor
delivery.
Compressed air filters contaminated.
Refrigeration compressor not supplied
power.
Condensate system malfunction.
Condenser dirty.
OPeRATIOn AnD MAInTenAnCe MAnUAL
ReMeDY
§
Check incoming power supply.
§
Check the control circuit fuse.
§
Check the transformer secondary windings
for the control voltage.
§ Change Star / Delta timer.
Top up coolant.
§ Set overload to correct value and switch to
manual reset.
§ Ensure voltage does not drop below 10% on
start up and % running.
Set pressure to correct rating for machine.
Change air filter, and separator element.
§ Ensure voltage does not drop below 10% on
start up and % running.
Correct incoming supply voltage.
† Change Airend.
Change air filter.
Set pressure to correct rating for machine.
Reduce site voltage to correct operating
voltage.
† Fit inlet valve service kit.
Replace or set pressure to correct rating for
machine.
† Fit blowdown solenoid service kit.
† Fit inlet valve service kit.
Fit new Separator element.
Set pressure to correct rating for machine.
† Fit Minimum pressure valve service kit.
† Fit blowdown solenoid service kit.
Fit new belt.
† Fix leaks.
† Fit inlet valve service kit.
Reduce demand or install additional
compressor.
Replace air filter elements.
Check incoming power supply.
Check the dryer protection fuse.
Check auxiliary contact on main motor
contactor.
Check operation of drain valve.
Check operation of condensate check valves.
Clean condenser and replace panel filter
element.
Check hot gas valve setting.

Publicidad

Tabla de contenido
loading

Tabla de contenido