Working instructions.
Before mounting or replacing application tools or accessories, remove the bat-
WARNING
tery. This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
Do not use accessories not specifically intended and recommended for this power tool by FEIN.
The use of non-original FEIN accessories can lead to overheating of the power tool and destroy
it.
For each job, use only the FEIN application tool released and intended for the
CAUTION
respective application.
Switching on and off (figure 10).
Always hold the power tool
CAUTION
firmly. Otherwise, you could
lose control over the power tool.
The power tool is equipped with a soft-start-
ing feature.
If the motor switches off after a proper
screwdriving operation, restarting is not pos-
sible until after 0.8 seconds. This prevents
accidental retightening of already tightened
screws.
In left rotation mode, the
CAUTION
power tool switches off with
significantly increased torque. Before putting
into operation, set the torque within the
specified limits on a suitable test bench.
Switching on:
To switch the power tool on after changing
the battery or after it having switched off,
press the switch for at least 0.2 seconds.
The operational readiness is signalled by the
lit LED.
When pressing the On/Off switch halfway in,
the light goes on.
When pressing the On/Off switch completely
in, the light and the power tool are on.
Switching off:
To switch off the power tool, release the
On/Off switch.
The power tool switches off approx. 30 min
after the last switch actuation, meaning, the
power tool can only be reactivated again by
switching on.
Fig. 10