CFX3
Alert messages
fig. o A, page 16.
E.g. see
Alert message
Description
!ALERT - Lid open
Lid open more
> 3 min
than 3 minutes
!ALERT - Voltage
The device has
low
stopped working
on DC due to low
voltage
The device has
stopped working
on DC due to
abnormally high
voltage >31.5 V
(unlikely event –
for electronics
protection only –
uses same alert
message as low
voltage above)
Warning codes
fig. o B, page 16.
E.g. see
Warning code
Fault
!WARNING 32
Fan over-current
!WARNING 33
Compressor start
fail
EN
Possible cause
•
Lid not fully
latched
•
Internal fault
•
Insufficient supply
voltage
•
Battery voltage is
too low
•
Battery protec-
tion is set too high
•
Wrong DC supply
voltage
specification
•
Faulty supply
voltage
•
Internal fault
Possible cause
Internal fault.
Troubleshooting
Suggested remedy
•
Check lid latched fully
•
Authorised repair centre
inspection required
•
Check voltage drop
from battery to power
outlet and increase wir-
ing gauge if necessary
•
Test the battery and
charge as needed
•
Select a lower battery
protection setting
•
Ensure DC supply volt-
age specification
matches CFX3 product
rating label
•
Check DC voltage sup-
ply & repair or replace if
faulty
•
Authorised repair centre
inspection required
Suggested remedy
Turn off the device for at
least 5 mins., then restart. If
the problem persists,
authorised repair centre
inspection required
35