Danger if battery is not monitored during conservation charging.
Serious injury and material damage can result, in particular due to short circuits, arcs and
oxyhydrogen explosions.
► Visually inspect the battery at a regular interval as specified by the manufacturer (but
► In the event of the following, do not start the device or switch it off immediately and
Danger following ignition of oxyhydrogen caused by sparks resulting from the
charging leads being disconnected too soon.
This can result in serious injury and damage to property.
► Before disconnecting the charging leads, press the Stop/Start button to finish buffering.
7
Interrupting "Re-
NOTE!
fresh" charging
Danger due to disconnecting or unplugging the connection sockets and connecting
plugs during reactivation.
This can result in damage to the connection sockets and connecting plugs.
► Do not disconnect or unplug charging leads while reactivating.
Resuming refresh
charging
WARNING!
at least once per week) to ensure the battery is filled to the max. marking with acid.
have the battery checked by an authorised workshop:
Uneven acid levels or high water consumption in individual cells
Impermissible warming of the battery to above 55 °C (131 °F).
WARNING!
To terminate "Refresh" charging:
6
-
Press the Stop/Start key
Disconnect the charger
Disconnect the black charging lead from the negative pole (-) of the battery
-
Disconnect the red charging lead from the positive pole (+) on the battery
-
Press the Stop/Start key while reactivating
1
-
Press the Stop/Start key
2
-
Refresh charging is resumed
"Refresh" charging is interrupted