GB
ENGLISH
INDEX
Key
Warnings
Responsibility
1. General
1.1 Description of the Integrated Inverter
1.2 Integrated expansion vessel
1.3 Integrated electropump
1.4 Technical characteristics
2. Installation
2.1 Vertical Configuration
2.1.1 Hydraulic connections
2.1.2 Loading operation – Installation above head and below head
2.2 Horizontal Configuration
2.2.1 Hydraulic connections
2.2.2 Orientation of the interface panel
2.2.3 Loading operation – Installation above head and below head
3. Commissioning
3.1 Electrical connections
3.2 Configuration of the integrated inverter
3.3 Priming
4. The keypad and the display
4.1 Direct access with a combination of keys
4.2 Access by name with a drop-down menu
4.3 Structure of the menu pages
4.4 Blocking parameter setting by Password
4.5 Enabling and disabling the motor
5. Meaning of the individual parameters
5.1 User Menu
5.1.1 Status
5.1.2 RS: Rotation speed display
5.1.3 VP: Pressure display
5.1.4 VF: Flow display
5.1.5 PO: Absorbed power display
5.1.6 C1: Phase current display
5.1.7 Operating hours and number of starts
5.1.8 PI: Power histogram
5.1.9 Output flow meter
5.1.10 VE: Version display
5.1.11 FF: Fault log display
5.2 Monitor Menu
37
5.2.1 CT: Display contrast
5.2.2 BK: Display brightness
40
5.2.3 TK: Backlight switch-on time
40
5.2.4 LA: Language
41
5.2.5 TE: Dissipator temperature display
5.3 Setpoint Menu
41
5.3.1 SP: Setting the setpoint pressure
42
5.4 Manual Menu
42
5.4.1 Status
43
5.4.2 RI: Speed setting
44
5.4.3 VP: Pressure display
44
5.4.4 VF: Flow display
5.4.5 PO: Absorbed power display
45
45
5.4.6 C1: Phase current display
5.4.7 RS: Rotation speed display
46
46
5.4.8 TE: Dissipator temperature display
47
5.5 Installer Menu
47
5.5.1 RP: Setting the pressure fall to restart
48
5.5.2 OD: Type of plant
5.5.3 MS: Measuring system
48
5.5.4 EK: Setting the low pressure function on suction
48
5.5.5 PK: Low pressure threshold on suction
49
5.5.6 T1: Low pressure delay (function detecting low pressure on suction)
49
5.6 Technical Assistance Menu
50
5.6.1 TB: Water lack blockage time
5.6.2 T2: Delay in switching off
51
54
5.6.3 GP: Proportional gain coefficient
5.6.4 GI: Integral gain coefficient
54
5.6.5 RM: Maximum speed
55
5.6.6 AY: Anti Cycling
55
5.6.7 AE: Enabling the anti-block function
56
5.6.8 AF: Enabling the anti-freeze function
56
5.7 Setting low pressure detection on suction
56
5.8 RF: Fault and warning reset
56
5.8.1 PW: Change password
56
6. Protection systems
56
6.1 Description of blockages
56
6.1.1 "BL" Anti Dry-Run (Protection against dry running)
56
6.1.2 "Anti-Cycling (Protection against continuous cycles without utility request)
56
56
6.1.3 "Anti-Freeze (Protection against freezing of water in the system)
6.1.4 "BP1" Blockage due to fault of the delivery pressure sensor
56
56
6.1.5 "BP2" Blockage due to fault of the suction pressure sensor
6.1.6 "PB" Blockage due to supply voltage outside specifications
57
57
6.1.7 "SC" Blockage due to short circuit between the motor phases
57
57
57
57
57
57
57
58
58
58
58
58
58
58
58
58
58
59
59
59
59
59
60
60
60
60
60
60
60
60
60
60
61
61
61
61
62
62
62
62
63
63
63
63