Wall Installation - DAB E.sybox Instrucciones Para La Instalación Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 560
GB
ENGLISH

9.2 - Wall installation

This product is already set up for installation hanging on the wall with
the DAB accessory kit, to be purchased separately. The wall installation
appears as in Fig.20.
9.3 - Installation with quick connection
DAB supplies an accessory kit for Quick Connection of the system. This
is a quick coupling base on which to make the connections to the plant
and from which the system can be simply connected or disconnected.
Advantages:
• possibility of making up the plant on-site, testing it, but remov
ing the actual system until the moment of delivery, avoiding
possible damage (accidental blows, dirt, theft, ...);
• it is easy for the Assistance service to replace the system with
a "spare" in the event of special maintenance.
The system mounted on its quick connection interface appears as in
Fig.21.
104
Figure 20
9.4 - Multiple Sets
9.4.1 - Introduction to multipump systems
By multipump systems we mean a pump set made up of a number of
pumps whose deliveries all flow into a common manifold. The devices
communicate with one another by means of the connection provided
(wireless).
The group may be made up of a maximum of 4 devices.
A multipump system is used mainly for:
• Increasing hydraulic performance in comparison with a single
device
• Ensuring continuity of operation in the event of a device devel-
oping a fault
• Sharing out the maximum power
9.4.2 - Making a multipump system
The hydraulic plant must be created as symmetrically as possible to
obtain a hydraulic load uniformly distributed over all the pumps.
Figure 21