DUO
DUO
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
DUOX CITYLINE KIT 1-2L
DUO
DUO
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
DUO
DUOX CITYLINE KIT 1-2L
DUO
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
X CITYLINE KIT 1-2L
DUO
DUO
X CITYLINE KIT 1-2L
TECHNICAL FEATURES
Power Supply
Consumption
in standby
audio active
IP43 / IK07
lighting
Audio power from the apartment to the panel
Audio power from the panel to the apartment
Operating Temperature
Adjustable volume both ways
Values:
- Lock-release activation time:
- Exit button activation time:
-
Maximum conversation time: 90 sec.
-
Panel type: sub-block/block/general, (default: block).
-
Block number: 00..99, (By default: 00).
-
Sub-Block number: 00..99, (By default: 00).
-
Panel number: 0..9, (By default: 0).
- Door sensor
time: 000..250, (By default: 000, not active).
- Opening
code: 0000..9999, (By default: not active).
- Programming
code: 0000..9999, (By default: 4444).
- MASTER
Panel: not active.
- Monitoring
volume: 0..9, (By default: 5).
-
Buttons´ sequential programming time after activity has stopped: 60 secs
-
Buttons´ inverse programming time after activity has stopped: 300 secs
Capacities:
•
Calls from the Button Panel: 99.
•
Calls from the Keypad panel:
-
Sub-Block: 99.
- Block:
9999.
- General Entrance: 999999.
•
Number of Panels:
- General entrances: 10.
- Block:
10.
-
Sub-Block: 10.
Power Supply
Consumption (±5%)
in standby
maximum
Maximum number of terminals per residence
Telephone address: 6 decimal digits
Working Temperature
Speaker
Microphone:
Electret
Call Ring tone Selection
Number of communication channels: 2 per BUS
Pag 12
01..99 sec. (By default: 03).
00..99 sec. (By default: 06).
Dynamic Resist. 50 Ω
18 Vdc
94 mA
550 mA
35 mA
1 W
0,15 W
[-10º , +60ºC]
[14º, 140ºF]
18 Vdc
16 mA
190 mA
3
000001...999999
[-5º,
+40ºC]
1.75" 16 Ω