Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
-
Open Photocell Function F.CH :
Connected between Term. N.17 and Term. 19 Contact N.C. Normally closed
This input is considered a safety, the contact can be interrupted at any time during opening by the
automation causing an immediate stop in movement, the automation will continue until the contact is
restored.
Stop function STP :
Connected to Term. N.18 and Term. N.19 Contact Normally Open N.C. This input is considered a safety
the contact can be interrupted at any time immediately stopping the automation disabling any function
including automatic closing.
-
Accessory power supply connection 24V AC 7 watts between Term. N.20 and N.21 max.
-
2nd radio channel connection (only if using 2-channel radio connector) between terminal N.22 and N.23
-
Antenna connection: between Term. N.24 (mesh) and N.25 (signal)
-
Thermal sensor connection:
connected from the motor. In the event of intervention only the first safety opening will be enabled. The
automation will NOT close until the normal operating temperature is restored
NB: if not used, it is necessary to short-circuit the contact
-
Selection of operating voltage: TRI-PHASE 400V AC between N.30 and N.29, SINGLE-PHASE 230V AC
between N.28 and N.29

PROGRAMMING

The great reliability of the system and the high concentration of the functions are managed by a micro-
controller so that the system can autonomously calculate all deceleration parameters and the working time
with no special programming by the installer.
The unit is equipped with basic programming that will provide you with the fundamental selected
parameters. Only the following procedure is required for first start-up:
Release the motor mechanically through the release panel and verify the precise connection of the
stops based on the opening and closing of the door. The LED corresponding to the affected stop
must SWITCH OFF with an activated stop
Close the door manually, carry out a P/P impulse by pressing the corresponding button; the first
action performed by the door is an OPENING. If this is not the case remove power from the system
so as to replace the opening with the closing
During OPENING the display will show OP
During CLOSING the display will show CL
If you have selected Automatic operation, TC will be shown in the pause time
With the automation closed, -- will be shown.
If ST (stop) is shown, it means that the MAN PRESENT function is enabled and
the complete opening or closing cycle has not ended.
By using a new P/P command check that the complete opening of the door is carried out up to the
stop. At this point press the P/P button again and check the complete closing of the door up to the
stop.
After having verified the correct complete opening and closing enable the deceleration based on the
desired percentage ( Par. E ) and the maximum motor force
N.B. with each variation of any parameter the control unit will, at the first start impulse, verify the working
time of the closed and open gate between the two stops. Only once this is carried out the enabling of the
deceleration can be verified
between Term. N.26 and N.27, the N.C. contact thermal sensor is
16
( Par.L )

Publicidad

Tabla de contenido
loading

Productos relacionados para electrovolta 900CT-380

Este manual también es adecuado para:

900ct-381900ct-380e900ct-381e

Tabla de contenido