4.3. UV lamp connection
Connect the UV lamp(s) installed within the UV reactor to the corresponding terminals on the control panel using the cables supplied with the
unit. To do this, open the connection boxes on both sides of the UV reactor, and connect the wires to the corresponding terminals. Once the
connection is made, close the connection boxes, making sure the seal is properly seated.
Should also connect the yellow/green cable (ground) to the terminal located for this purpose in the UV reactor on the inlet flange.
Warning
Prior to the installation or replacement of any system component make sure it has been
previously disconnected from the mains, and there is no water flow through it.
Check all the electrical connectors are well tightened to avoid false contacts and their
consequent overheating.