Symbols; Technical Data - SATA SATAjet 3000 B Instrucciones De Servicio

Ocultar thumbs Ver también para SATAjet 3000 B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 142
Operating Instructions SATAjet 3000 B RP/HVLP (DIGITAL)
Content [Original Version: German]
1.
Symbols ................................ 115
2.
Technical Data ...................... 115
3.
Scope of Delivery ................. 116
4.
5.
Intended Use ........................ 117
6.
Safety Instructions ................ 117
7.
Use ....................................... 120
1.

Symbols

Warning! Risk which could cause heavy injuries or death.
Attention! Risk which could cause damage.
Explosion risk! Warning against risk which could cause
heavy injuries or death.
Notice! Useful tips and recommendations.
2.

Technical Data

Recommended spray gun inlet pressure
RP
HVLP
Compliant
Compliant legislation Lom-
bardy/Italy
Recommended spraying distance
RP
HVLP
HVLP Lombardy/Italy
Max. spray gun inlet pressure
8.
9.
Maintenance ......................... 123
10. Troubleshooting .................... 126
11. Disposal ................................ 128
12. After Sale Service ................. 129
13. Warranty / Liability ................ 129
14. Spare Parts .......................... 129
2.0 bar - 2.5 bar
2.0 bar
> 2.0 bar (air cap pressure > 0.7 bar)
< 2.5 bar (air cap pressure < 1.0 bar)
17 cm - 21 cm
13 cm - 17 cm
13 cm - 21 cm
10.0 bar
EN
115

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido