repairs at the unit / appendix
11.9
ImpAcT 1040 coNNecTIoN DIAgrAm
Switch
Blue
P/N 0522053
Ground
12
AppeNDIx
12.1
SelecTIoN of TIp
To achieve faultless and rational working, the selection of the
tip is of the greatest importance.
In many cases the correct tip can only be determined by means
of a spraying test.
Some ruleS for ThIS:
The spray jet must be even.
If streaks appear in the spray jet the spraying pressure is either
too low or the viscosity of the coating material to high.
remeDy: Increase pressure or dilute coating material. Each
pump conveys a certain quantity in proportion to the size of
the tip:
The following principle is valid:
There is a large range of tips with various spraying angles.
28
Ground
Blue / White
Black / Brown
Brown
Blue / White
Surge suppressor
P/N 0551758
Fan
large tip = low pressure
small tip = high pressure
EMI Filter
Blue / White
P/N 0522052
Green / Yellow
Ground
Fuse block
Fuse
Black
White
White
Red
Black
Motor
12.2
ServIcINg AND cleANINg of AIrleSS
hArD-meTAl TIpS
STANDArD TIpS
If a diferent tip type has been itted, then clean it according to
manufacturer's instructions.
The tip has a bore processed with the greatest precision. Careful
handling is necessary to achieve long durability. Do not forget
the fact that the hard-metal insert is brittle! Never throw the tip
or handle with sharp metal objects.
The following points must be observed to keep the tip
clean and ready for use:
1. Turn the relief valve handle fully counterclockwise (k
Circulation).
2. Remove the tip from the spray gun.
3. Place tip in an appropriate cleaning agent until all coating
material residue is dissolved.
4. If there is high-pressure air available, blow out tip.
5. Remove any residue by means of a sharp wooden rod
(toothpick).
6. Check the tip with the help of a magnifying glass and, if
necessary, repeat points 3 to 5.
Impact 1040
Power Cord
Black /
Brown
Capacitor
Black
Red
Motor controller
Red (+)
Black (-)
L.E.D.
Hall sensor
Potentiometer
Pressure sensor