Cabinet Finish:
Cylinder:
Motor:
(Nonreversing Models)
Boiler Horsepower:
Max. Air Flow:
Net Weight:
50 LB.
CYLINDER
M414670
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
50 Pound Steam Tumbler
Electrostatically applied thermosetting polyester.
37" x 30" (94 x 76.2 cm) perforated galvanized steel with four baffles;
50 pounds (22.7 kg) dry weight (cotton load)
High Pressure Steam — 1/2 H.P.
Low Pressure Steam — 3/4 H.P
Both motors are lifetime lubricated, internal overload protected
See below for reversing models.
High Pressure Steam (6 Coil) — 4.60 B.H.P.
Low Pressure Steam (4 Coil) — 3.00 B.H.P.
750 C.F.M. (354 liters/sec)
4 Coil Tumbler — 565 pounds (257 kg) (approximate)
6 Coil Tumbler — 580 pounds (263 kg) (approximate)
REVERSING MOTOR SIZES
GAS
FAN
1/3 H.P.
1/3 H.P.
ELECTRIC
HIGH
PRESSURE
1/3 H.P.
1/3 H.P.
1/3 H.P.
1/3 H.P.
STEAM
LOW
PRESSURE
1/2 H.P.
1/3 H.P.