SQUARING THE BLADE TO THE MITER TABLE
See Figures 19 - 23.
 Unplug the saw.
 Pull the saw arm all the way down and engage the lock
pin to hold the saw arm in transport position.
 Unlock the miter lock lever.
 Rotate the miter table until the pointer aligns with zero
detent on the miter scale.
 Lock the miter lock.
 Loosen bevel lock knob and set saw arm at 0
set 90
to miter table). Tighten bevel lock knob at stop.
°
 Place a square against the miter table and the flat part
of saw blade.
NOTE: Make sure that the square contacts the flat part
of the saw blade, not the blade teeth.
 Rotate the blade by hand and check the blade-to-table
alignment at several points.
 The edge of the square and the saw blade should be
parallel as shown in figure 21.
 If the top or bottom of the saw blade angles away from
the square as shown in figures 22 and 23, adjustments
are needed.
 Loosen the bevel lock knob.
 Adjust positive stop adjustment screw to bring saw blade
into alignment with the square. See Positive Stop Adjust-
ment in the Adjustments section.
 Retighten bevel lock knob. Recheck blade-to-table align-
ment.
NOTE: The above procedure can be used to check blade
squareness of the saw blade to the miter table at both 0
and 45
angles.
°
The saw has two scale indicators, one on the bevel scale
and one on the miter scale. After squaring adjustments have
been made, it may be necessary to loosen the indicator
screws and reset them to zero. See figure 20.
ASSEMBLY
BEVEL
LOCK KNOB
bevel (blade
°
°
VIEW OF BLADE NOT SQUARE WITH MITER TABLE,
18
COMBINATION
SQUARE
VIEW OF BLADE NOT SQUARE WITH MITER
TABLE, ADJUSTMENTS ARE REQUIRED
ADJUSTMENTS ARE REQUIRED
BLADE
MITER
TABLE
Fig. 22
Fig. 23