WARNING
Cables may twist or kink. Fingers, hands or other
body parts can be crushed or broken.
• Use foot switch.
• Wear gloves.
• Do not use with damaged or worn electrical cords.
• Keep guards in place.
• Place machine close to inlet.
• Plug cord into grounded three-prong receptacle.
• Wear safety glasses.
• Keep foot switch in working order.
• Test Ground Fault Circuit Interrupter (GFCI) to insure
proper operation.
READ ABOVE WARNING CAREFULLY!

Machine Safety

1. Wear standard equipment glove provided with
the machine. Never grasp a rotating cable with a
cloth or loose fitting glove. It could get wrapped
around the cable and cause serious injury.
2. Never operate machine with belt guard removed.
Fingers can be caught between the belt and pulley.
3. Do not overstress cables. Keep one hand on the
cable for control when the machine is running.
Overstressing cables because of obstruction may
cause twisting or kinking and result in serious injury.
4. Position machine within two feet of inlet. Use
Front End Guide Hose when it is difficult to locate
the machine near the access or clean out. Greater
distances can result in cable twisting or kinking.
5. Do not operate machine in (REV) reverse. Oper-
ating machine in reverse can result in cable damage
and is used only to back tool out of an obstruction.
6. Operate machine from the side with the
FOR/OFF/REV Switch. Allows for better control of
the machine.
4
K-375 Drain Cleaning Machine
Ridge Tool Company • Elyria, Ohio • U.S.A.
7. Use Rear Guide Hose. Prevents cable from whipping
and picking up debris.
8. Be careful when cleaning drains where cleaning
compounds have been used. Avoid direct contact
with skin and eyes. Serious burns can result from
some drain cleaning compounds.
9. Machine is made to clean drain lines. Follow in-
structions in operator's manual on machine uses.
Other uses may increase the risk of injury.
10. Do not use if foot switch, ON/OFF Switch, ground
plug or GFCI are broken. Poorly maintained tools
can result in serious injury.
SAVE THESE INSTRUCTIONS!
Description, Specifications and
Standard Equipment
Description
The RIDGID/Kollmann K-375 Drain Cleaning Machine will
clean up to 4 inch lines through 75 feet. It is equipped with
a quiet, powerful
1
/
H.P. reversible motor and features a
3
lightweight, corrosion resistant, molded plastic drum.

Specifications

Line Capacity ................Recommended for indoor drain
Drum Capacity .............75' of
Motor Type...................115V/60 Hz, Reversible,
Rating ..........................
Weight Machine Only...28 lbs.
Length..........................22"
Width............................13"
Height ..........................20"

Features

• Molded Plastic Drum – Will not rust, even when ex-
posed to the harshest chemical drain cleaning agents.
• Quick and Easy Drum Changeout – Quick release
mechanism makes drum removal simple. Release
and remove the drum in one, quick motion. No tools
necessary.
• Pneumatic Foot Actuator – Made from durable PVC
for long life in damp environments.
lines: 3" lines through 100' and
4" lines through 75'
1
/
" or 100' of
3
/
" cable
2
8
Split Phase, AC 240V/50Hz
Available on request
1
/
HP @ 1725 RPM
3

Publicidad