User Manual
OVERCURRENT DETECTION
AUTOMATIC DISCONNECTION OF THE
BATTERY
The battery disconnects automatically
EN
in the unlikely event of an overcurrent
detection. The ELB 1200 unit will shut down
automatically.
BATTERY RECONNECTION
If the source causing the overcurrent is
removed the battery will return to its normal
mode (the battery will try to reconnect in 12
sec intervals).
OVERVOLTAGE DETECTION
AUTOMATIC DISCONNECTION OF THE
BATTERY
The battery disconnects automatically in the
unlikely event of an overvoltage detection.
Even if overvoltage occurs the battery can
be discharged (used with the flash unit).
BATTERY RECONNECTION
Discharging the battery will bring it back to
its normal mode.
OVERHEAT DETECTION
AUTOMATIC DISCONNECTION OF THE
BATTERY
When the internal battery temperature
reaches 60 °C the battery terminals are
disconnected. Please allow the unit to cool
down.
BATTERY RECONNECTION
As soon as the internal temperature
reduces below 55 °C the battery returns to
automatically the normal mode.
9