Hammer Safety Warnings; Additional Safety Precautions - Hilti TE 1 Manual De Instrucciones

Ocultar thumbs Ver también para TE 1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
5.1.5 Service
a) Have your power tool serviced by a qualified repair
person using only identical replacement parts.
This will ensure that the safety of the power tool is
maintained.

5.2 Hammer safety warnings

a) Wear ear protectors. Exposure to noise can cause
hearing loss.
b) Use auxiliary handles, if supplied with the tool.
Loss of control can cause personal injury.
c) Hold power tool by insulated gripping surfaces,
when performing an operation where the cutting
accessory may contact hidden wiring or its own
cord. Cutting accessory contacting a "live" wire may
make exposed metal parts of the power tool "live"
and could give the operator an electric shock.

5.3 Additional safety precautions

5.3.1 Personal safety
a) Keep the grips dry, clean and free from oil and
grease.
b) Check that the side handle is fitted correctly and
tightened securely.
c) Wear a dust mask.
d) Improve the blood circulation in your fingers by
relaxing your hands and exercising your fingers
during breaks between working.
e) Children must be instructed not to play with the
power tool.
f)
The power tool is not intended for use by children,
by debilitated persons or those who have received
no instruction or training.
g) Avoid touching rotating parts. Switch the power
tool on only after bringing it into position at the
workpiece. Touching rotating parts, especially rotat-
ing insert tools, may lead to injury.
h) Always lead the supply cord and extension cord
away from the power tool to the rear while work-
ing. This helps to avoid tripping over the cord while
working.
i)
Dust from material such as paint containing lead,
some wood species, minerals and metal may be
harmful. Contact with or inhalation of the dust may
cause allergic reactions and/or respiratory diseases
to the operator or bystanders. Certain kinds of dust
are classified as carcinogenic such as oak and beech
dust especially in conjunction with additives for wood
conditioning (chromate, wood preservative). Material
containing asbestos must only be treated by special-
ists. Where the use of a dust extraction device is
possible it shall be used. To achieve a high level
of dust collection, use a suitable vacuum cleaner
of the type recommended by Hilti for wood dust
and/or mineral dust together with this tool. Ensure
that the workplace is well ventilated. The use of a
dust mask of filter class P2 is recommended. Fol-
low national requirements for the materials you
want to work with.
5.3.2 Power tool use and care
a) Secure the workpiece. Use clamps or a vice to
secure the workpiece. The workpiece is thus held
more securely than by hand and both hands remain
free to operate the power tool.
b) Check that the insert tools used are compatible
with the chuck system and that they are secured
in the chuck correctly.
c) In the event of a power failure or interruption in the
electric supply, switch the power tool off, unplug
the supply cord and release the switch lockbutton
(if applicable). This will prevent accidental restarting
when the electric power returns.
d) Avoid applying an excessive amount of grease to
the drill bit connection end. Grease may otherwise
be forced out of the chuck when the power tool is in
operation.
5.3.3 Electrical safety
a) Before beginning work, check the working area
(e.g. using a metal detector) to ensure that no
concealed electric cables or gas and water pipes
are present. External metal parts of the power tool
may become live, for example, when an electric cable
is damaged accidentally. This presents a serious risk
of electric shock.
b) Check the power tool's supply cord at regular
intervals and have it replaced by a qualified spe-
cialist if found to be damaged. If the power tool's
supply cord is damaged it must be replaced with
a specially-prepared supply cord available from
Hilti Customer Service. Check extension cords
at regular intervals and replace them if found to
be damaged. Do not touch the supply cord or
extension cord if it is damaged while working.
Disconnect the supply cord plug from the power
outlet. Damaged supply cords or extension cords
present a risk of electric shock.
c) Dirty or dusty power tools which have been used
frequently for work on conductive materials
should be checked at regular intervals at a Hilti
Service Center. Under unfavorable circumstances,
dampness or dust adhering to the surface of
the power tool, especially dust from conductive
materials, may present a risk of electric shock.
d) When working outdoors with an electric tool
check to ensure that the tool is connected to the
electric supply by way of a ground fault circuit
interrupter (RCD) with a rating of max. 30 mA
(tripping current). Use of a ground fault circuit
interrupter reduces the risk of electric shock.
e) Use of a ground fault circuit interrupter (RCD
residual current device) with a maximum tripping
current of 30 mA is recommended.
en