taking out the frame the filter can be changed
easily. The installation is made in reverse
order.
By some extractor hoods the active carbon
filter is directly mounted on the metal filter.
After the removal of the metal filters take
the charcoal filter out and substitute it by a
new one. Important: please do not clean
the active carbon filter with water or any other
liquid.
Lighting LED
option: Halogen Replacing the light bulbs 20 Watt
Switch off the extractor hood and pull
out the mains plug or switch off the
electricity supply at the fuse box.
Replace faulty lights through new ones
immediately.
Please cut the connection between the
extractor hood and the power supply
system!
The lightings remain hot for some time.
Please wait therefore for some time till the
lightings have cooled off.
After cooling-off the glass cover is to be
removed with a small screwdriver. Then the
lighting can be taken out. Please avoid any
skin contact with the luminous means. Af-
ter the exchange press the glass pane
lightly to a certain extent (lock in of the pane).
Restore the power by inserting the mains
plug or switching on the fuse.
Note: If the light does not function, check
that the bulbs have been inserted correctly.
Exchange of the lighting hologen
(option 35 Watt)
Please cut the connection between the
extractor hood and the power supply
system!
The lighting remains hot for some time.
Please wait therefore for some time till the
lighting has cooled off.
For the exchange of the lighting at first
please take the retaining ring (c) out of the
extractor hood with a screwdriver.
Afterwards solve the plug of the light bulb
(a) and separate it from the fixture. Therefore
the feather ring (b) must be crushed and
be removed upwards. The installation of
the new lighting is made in reverse order.