<< Operating instructions SATA filter 400 >>
US
Information!
• Fineness 5µm
• Surface 100 cm²
The requested outlet pressure can be adjusted at the pressure regulation
valve [1-4] with the pressure regulation button [1-5] and at the pressure
gauge [1-5].
If a certain condensate amount is exceeded, the automatic condensate
drain valve [1-9] opens under pressure. The condensate will be drained
through the condensate drain hose [1-10] into the container (not included
in delivery). Only a small condensate amount remains.
9.2. Filter stage [B]:
The fine filter cartridge (Art. No. 81810) of the second filter stage sepa-
rates smallest particles.
Information!
Fine filter cartridge:
• Special microfiber fleece
• Fineness 0.01 µm, separation degree 99.998 % related to a particle
size > 0.01 µm
• Surface 300 cm²
9.3. Filter stage [C]:
Except for the installed filter cartridge, the design of the third filter stage is
identical to the second filter stage [B]. This third filter stage contains the
activated charcoal cartridge (Art. No. 85373). The activated charcoal
filter can only be used with the filter stages [A] and [B] preceding.
Information!
Activated charcoal filter cartridge:
• Fiber-bound activated charcoal
• Surface 300 cm²
9.4. Air outlet module [D]:
The outlet module is equipped with 2 ball valves [1-6], connection thread
G ¼ a
XXVI.6