Mitsubishi Mr.Slim Serie Para El Instalador página 5

Tabla de contenido

Publicidad

8
[Fig. 8-3]
A Indoor terminal block
2
1 2
5
1
6
3
D Outdoor terminal block
7
E Power supply cord
[Fig. 8-4]
A
C
[Fig. 8-5]
A
C
F
I
H
A For installation in the switch box:
B For direct installation on the wall select one of the following:
• Prepare a hole through the wall to pass the remote controller cord (in order to run the remote controller cord from
the back), then seal the hole with putty.
• Run the remote controller cord through the cut-out upper case, then seal the cut-out notch with putty similarly as
above.
[Fig. 8-6]
A
[Fig. 8-7]
2
3 4
1
TEMP.
ON/OFF
F
MENU
ON/OFF
E
BACK
MONITOR/SET
DAY
PAR-21MAA
CLOCK
OPERATION
G
C
D
B Earth wire (green/yellow)
4
C Indoor/outdoor unit
connecting wire
2
3-core 1.5 mm
or
more
L N
B
30
30
46
B
B-1.
D
E
G
I
AB
TB6
B
4
A
FILTER
CHECK
TEST
B
CLEAR
1
8.2
A Indoor terminal block
B Earth wire (green/yellow)
C Indoor/outdoor unit connecting wire 3-
2
core 1.5 mm
or more
D Outdoor terminal block
E Power supply cord
1 Connecting cable
2
Cable 3-core 1.5 mm
, in conformity
with Design 245 IEC 57.
2 Indoor terminal block
3 Outdoor terminal block
8.3
A Remote controller profile
B Required clearances surrounding the remote controller
C Installation pitch
B-2.
H
I
A To the terminal block on the indoor unit
B TB6 (No polarity)
8.4
1
2
4 Always install an earth wire (1-core 1.5 mm
longer than other cables
5 Remote controller cable
Wire No × size (mm
) : Cable 2C × 0.3
2
This wire accessory of remote controller
(wire length : 10m, non-polar. Max. 500m)
6 Wired remote controller (option)
7 Power supply cord
H
J
C Wall
D Conduit
E Lock nut
F Bushing
G Switch box
H Remote controller cord
I Seal with putty
J Wood screw
⁄ Mode number
1
⁄ Setting number
2
⁄ Refrigerant address
3
⁄ Unit number
4
A Filter
button (<Enter> button)
B TEST button
C Set Time button
D Timer On/Off button (Set Day button)
E Mode selection button
F Set temperature button
G Timer Menu button (Monitor/Set button)
2
)
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sez-kd25Kd35Kd50Kd60Kd71vaq

Tabla de contenido